IDEC MICRO/I HG2J-7U Hardware Manual page 103

Table of Contents

Advertisement

5.8 Wiring
• Turn off the power supply before wiring.
• Make the wiring as short as possible and run all wires as far away as possible from high-voltage and large-
current cables. Follow all the procedures and precautions when wiring the HG1P.
• Separate the HG1P power supply wiring from the power lines of I/O devices and motor equipment.
• Ground the functional earth terminal to make sure of correct operation.
HG1P Optional Cable (HG9Z-XCP13/-XCP15/-XCP17)
This cable connects the HG1P and external devices.
Specifications
Communication Interface
Connector for the External Devices
Length
Outline Drawing
Connector for the External Devices
1
14
(View of mating surface of the removable connector)
Connector Wiring Table
No.
Name
1
FG
Frame Ground
2
RDB-/TP1-
Receive Data (-)
3
RDA+/TP1+ Receive Data (+)
4
SDB-/TP0-
Send Data (-)
5
SDA+/TP0+ Send Data (+)
6
SG
Communication Signal Ground
7
NC
8
NC
9
B_NO1
Enabling Switch Contact 1 (NO)
10
B_C1
Enabling Switch Contact 1 (COM)
11
A_NC11
Emergency Stop Switch Contact 1 (NC)
12
A_NC12
Emergency Stop Switch Contact 1 (NC)
13
DC24V-
Main unit 24V DC Power Supply (-)
Serial Interface (RS422/485) or Ethernet Interface
D-sub 25-pin Male Connector (Jackscrew M2.6)
3m, 5m, 7m
13
25
Function
-
-
MICRO/I Hardware Manual
Cable Length 3m, 5m, 7m
No.
Name
14
NC
15
NC
16
NC
17
NC
18
C_NC1
Selector Switch Contact 1 (NC)
19
C_NO1
Selector Switch Contact 1 (NO)
20
C_C1
Selector Switch Contact 1 (COM)
21
B_NO2
Enabling Switch Contact 2 (NO)
22
B_C2
Enabling Switch Contact 2 (COM)
23
A_NC21 Emergency Stop Switch Contact 2 (NC)
24
A_NC22 Emergency Stop Switch Contact 2 (NC)
25
DC24V+ Main unit 24V DC Power Supply (+)
5 HG1P
Function
-
-
-
-