Updating The Dmi/Smbios Data - Lenovo System x3550 M3 Problem Determination And Service Manual

Table of Contents

Advertisement

The following commands are examples of using the userid and password default values and not
using the default values:
Example that does not use the userid and password default values:
asu set SYSTEM_PROD_DATA.SysInfoUUID <uuid_value> --user <user_id>
--password <password>
Example that does use the userid and password default values:
asu set SYSTEM_PROD_DATA.SysInfoUUID <uuid_value>
• Online KCS access (unauthenticated and user restricted): You do not need to specify a value for
access_method when you use this access method.
Example:
asu set SYSTEM_PROD_DATA.SysInfoUUID <uuid_value>
The KCS access method uses the IPMI/KCS interface. This method requires that the IPMI driver
be installed. Some operating systems have the IPMI driver installed by default. ASU provides the
corresponding mapping layer. See
Advanced Settings Utility Users Guide for more details.
• Remote LAN access, type the command:
Note: When using the remote LAN access method to access IMM using the LAN from a client,
the host and the imm_external_ip address are required parameters.
host <imm_external_ip> [user <imm_user_id>][password <imm_password>]
Where:
imm_external_ip
The external IMM LAN IP address. There is no default value. This parameter is required.
imm_user_id
The IMM account (1 of 12 accounts). The default value is USERID.
imm_password
The IMM account password (1 of 12 accounts). The default value is PASSW0RD (with a zero
0 not an O).
The following commands are examples of using the userid and password default values and not
using the default values:
Example that does not use the userid and password default values:
asu set SYSTEM_PROD_DATA.SysInfoUUID <uuid_value> --host <imm_ip>
--user <user_id> --password <password>
Example that does use the userid and password default values:
asu set SYSTEM_PROD_DATA.SysInfoUUID <uuid_value> --host <imm_ip>
• Bootable media: You can also build a bootable media using the applications available through
the Tools Center website at
. From the left pane, click IBM System x and BladeCenter Tools Center, then click
CENTER
Tool reference for the available tools.
Step 4.
Restart the server.

Updating the DMI/SMBIOS data

The Desktop Management Interface (DMI) must be updated when the system board is replaced. Use the
Advanced Settings Utility to update the DMI in the UEFI-based server.
"IBM Advanced Settings Utility program" on page 528