Table 9. DSA Preboot messages (continued)
• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
Chapter 4 "Parts listing, Lenovo System x3550 M3 Type 4254 and 7944" on page 403
• See
components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
• If an action step is preceded by "(Trained service technician only)", that step must be performed only by a
Trained service technician.
• Go to the IBM support website at
tips, and new device drivers or to submit a request for information.
Message
Compo-
number
nent
166-812-
IMM
xxx
System x3550 M3Problem Determination and Service Guide
330
http://www.ibm.com/supportportal/
Description
Test
State
IMM I2C
Abor-
IMM I2C
Test
ted
Test
aborted: a
parameter is
out of range.
to determine which
to check for technical information, hints,
Action
http://www.ibm.com/support/entry/portal/
docdisplay?lndocid=SERV-CALL
1. Turn off the system and disconnect it from
the power source. You must disconnect the
system from ac power to reset the IMM.
2. After 45 seconds, reconnect the system to
the power source and turn on the system.
3. Run the test again.
4. Make sure that the DSA code is at the latest
level. For the latest level of DSA code, go to
http://www.ibm.com/support/entry/portal/
docdisplay?lndocid=SERV-DSA
5. Make sure that the IMM firmware is at the
latest level. The installed firmware level is
shown in the DSA event log in the Firmware/
VPD section for this component. For more
information, see
"Updating the firmware" on
page
513.
6. Run the test again.
7. If the failure remains, go to the IBM website
for more troubleshooting information at
http://www.ibm.com/support/entry/portal/
docdisplay?lndocid=SERV-CALL
.
.
.