Lenovo System x3550 M3 Problem Determination And Service Manual page 72

Table of Contents

Advertisement

User Response
1. Check power supply n LED. 2. Remove the failing power supply. 3. (Trained technician only)
Replace the system board. (n = power supply number) Planar 3.3V : Planar 5V :
• 80010b01-0c01xxxx : Numeric sensor [NumericSensorElementName] going high (upper non-
recoverable) has asserted. (Ambient Temp)
This message is for the use case when an implementation has detected an Upper Non-recoverable sensor
going high has asserted.
May also be shown as 80010b010c01xxxx or 0x80010b010c01xxxx
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0498
User Response
Check the server airflow. Make sure that nothing is blocking the air from coming into or preventing the
air from exiting the server.
• 80030012-2301xxxx : Sensor [SensorElementName] has deasserted. (OS RealTime Mod)
This message is for the use case when an implementation has detected a Sensor has deasserted.
May also be shown as 800300122301xxxx or 0x800300122301xxxx
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0509
User Response
No action; information only.
• 80070201-0301xxxx : Sensor [SensorElementName] has transitioned to critical from a less severe
state. (CPU 1 OverTemp)
System x3550 M3Problem Determination and Service Guide
60

Advertisement

Table of Contents
loading

This manual is also suitable for:

42547944

Table of Contents