Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0138
User Response
1. Check the IBM support website for an applicable retain tip or firmware update that applies to this
memory error. 2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or
the event logs) to a different memory channel or microprocessor. 3. If the problem follows the DIMM,
replace the failing DIMM. 4. (Trained technician only) If the problem occurs on the same DIMM
connector, check the DIMM connector. If the connector contains any foreign material or is damaged,
replace the system board. 5. (Trained technician only) Remove the affected microprocessor and
check the microprocessor socket pins for any damaged pins. If a damage is found, replace the
system board. 6. (Trained technician only) Replace the affected microprocessor. 7. Manually re-
enable all affected DIMMs if the server firmware version is older than UEFI v1.10. If the server
firmware version is UEFI v1.10 or newer, disconnect and reconnect the server to the power source
and restart the server. 8. (Trained Service technician only) Replace the affected microprocessor.
• 806f010c-2011xxxx : Uncorrectable error detected for [PhysicalMemoryElementName] on
Subsystem [MemoryElementName]. (DIMM 17)
This message is for the use case when an implementation has detected a Memory uncorrectable error.
May also be shown as 806f010c2011xxxx or 0x806f010c2011xxxx
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0138
User Response
1. Check the IBM support website for an applicable retain tip or firmware update that applies to this
memory error. 2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or
the event logs) to a different memory channel or microprocessor. 3. If the problem follows the DIMM,
replace the failing DIMM. 4. (Trained technician only) If the problem occurs on the same DIMM
connector, check the DIMM connector. If the connector contains any foreign material or is damaged,
replace the system board. 5. (Trained technician only) Remove the affected microprocessor and
check the microprocessor socket pins for any damaged pins. If a damage is found, replace the
.