Lenovo System x3550 M3 Problem Determination And Service Manual page 79

Table of Contents

Advertisement

This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
May also be shown as 80070201200axxxx or 0x80070201200axxxx
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0522
User Response
1. Make sure that the fans are operating, that there are no obstructions to the airflow (front and rear of
the server), that the air baffles are in place and correctly installed, and that the server cover is installed
and completely closed. 2. Check the ambient temperature. You must be operating within the
specifications (see Features and specifications for more information). 3. Make sure that the heat sink
for microprocessor n is installed correctly. 4. (Trained technician only) Replace microprocessor n. (n =
microprocessor number)
• 80070201-200bxxxx : Sensor [SensorElementName] has transitioned to critical from a less severe
state. (DIMM 11 Temp)
This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
May also be shown as 80070201200bxxxx or 0x80070201200bxxxx
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0522
User Response
1. Make sure that the fans are operating, that there are no obstructions to the airflow (front and rear of
the server), that the air baffles are in place and correctly installed, and that the server cover is installed
and completely closed. 2. Check the ambient temperature. You must be operating within the
specifications (see Features and specifications for more information). 3. Make sure that the heat sink
.