Prefix: PLAT ID: 0368
User Response
No action; information only.
• 806f0107-0301xxxx : An Over-Temperature Condition has been detected on
[ProcessorElementName]. (CPU 1)
This message is for the use case when an implementation has detected an Over-Temperature Condition
Detected for Processor.
May also be shown as 806f01070301xxxx or 0x806f01070301xxxx
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0036
User Response
1. Make sure that the fans are operating. There are no obstructions to the airflow (front and rear of the
server), the air baffles are in place and correctly installed, and the server cover is installed and
completely closed. 2. Make sure that the heat sink for microprocessor n is installed correctly. 3.
(Trained technician only) Replace microprocessor n. (n = microprocessor number)
• 806f0107-0302xxxx : An Over-Temperature Condition has been detected on
[ProcessorElementName]. (CPU 2)
This message is for the use case when an implementation has detected an Over-Temperature Condition
Detected for Processor.
May also be shown as 806f01070302xxxx or 0x806f01070302xxxx
Severity
Error
Serviceable
Yes
.