Lenovo System x3550 M3 Problem Determination And Service Manual page 141

Table of Contents

Advertisement

DIMMs are firmly seated and no foreign material is found in the DIMM connector. Then, retry with the
same DIMM. 3. If the problem is related to a DIMM, replace the failing DIMM indicated by the error
LEDs. 4. If the problem occurs on the same DIMM connector, swap the affected DIMMs (as indicated
by the error LEDs on the system board or the event logs) to a different memory channel or
microprocessor. 5. (Trained technician only) If the problem occurs on the same DIMM connector,
check the DIMM connector. If the connector contains any foreign material or is damaged, replace the
system board. 6. (Trained service technician only) Remove the affected microprocessor and check
the microprocessor socket pins for any damaged pins. If a damage is found, replace the system
board. 7. (Trained service technician only) If the problem is related to microprocessor socket pins,
replace the system board.
• 806f030c-2003xxxx : Scrub Failure for [PhysicalMemoryElementName] on Subsystem
[MemoryElementName]. (DIMM 3)
This message is for the use case when an implementation has detected a Memory Scrub failure.
May also be shown as 806f030c2003xxxx or 0x806f030c2003xxxx
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0136
User Response
Note: Each time you install or remove a DIMM, you must disconnect the server from the power
source; then, wait 10 seconds before restarting the server. 1. Check the IBM support website for an
applicable retain tip or firmware update that applies to this memory error. 2. Make sure that the
DIMMs are firmly seated and no foreign material is found in the DIMM connector. Then, retry with the
same DIMM. 3. If the problem is related to a DIMM, replace the failing DIMM indicated by the error
LEDs. 4. If the problem occurs on the same DIMM connector, swap the affected DIMMs (as indicated
by the error LEDs on the system board or the event logs) to a different memory channel or
microprocessor. 5. (Trained technician only) If the problem occurs on the same DIMM connector,
check the DIMM connector. If the connector contains any foreign material or is damaged, replace the
system board. 6. (Trained service technician only) Remove the affected microprocessor and check
the microprocessor socket pins for any damaged pins. If a damage is found, replace the system
board. 7. (Trained service technician only) If the problem is related to microprocessor socket pins,
replace the system board.
• 806f030c-2004xxxx : Scrub Failure for [PhysicalMemoryElementName] on Subsystem
[MemoryElementName]. (DIMM 4)
This message is for the use case when an implementation has detected a Memory Scrub failure.
May also be shown as 806f030c2004xxxx or 0x806f030c2004xxxx
Severity
Error
.
Chapter 3
Diagnostics
129