Lenovo System x3550 M3 Problem Determination And Service Manual page 107

Table of Contents

Advertisement

Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0222
User Response
If the NMI button has not been pressed, complete the following steps: 1. Make sure that the NMI
button is not pressed. 2. Replace the operator information panel cable. 3. Replace the operator
information panel.
• 806f0021-2201xxxx : Fault in slot [PhysicalConnectorSystemElementName] on system
[ComputerSystemElementName]. (No Op ROM Space)
This message is for the use case when an implementation has detected a Fault in a slot.
May also be shown as 806f00212201xxxx or 0x806f00212201xxxx
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0330
User Response
1. Check the PCI LED. 2. Reseat the affected adapters and riser card. 3. Update the server firmware
(UEFI and IMM) and adapter firmware. Important: Some cluster solutions require specific code levels
or coordinated code updates. If the device is part of a cluster solution, verify that the latest level of
code is supported for the cluster solution before you update the code. 4. Remove both adapters. 5.
Replace the riser cards. 6. (Trained service technicians only) Replace the system board.
• 806f0021-2582xxxx : Fault in slot [PhysicalConnectorSystemElementName] on system
[ComputerSystemElementName]. (All PCI Error)
This message is for the use case when an implementation has detected a Fault in a slot.
May also be shown as 806f00212582xxxx or 0x806f00212582xxxx
Severity
Error
Serviceable
.
Chapter 3
Diagnostics
95

Advertisement

Table of Contents
loading

This manual is also suitable for:

42547944

Table of Contents