Endress+Hauser Proline Promass H 300 PROFINET Operating Instructions Manual page 104

Coriolis flowmeter
Table of Contents

Advertisement

Commissioning
Parameter
Assign frequency output
Minimum frequency value
Maximum frequency value
104
Prerequisite
The Frequency option is
selected in the Operating
mode parameter (→  101).
The Frequency option is
selected in the Operating
mode parameter (→  101)
and a process variable is
selected in the Assign
frequency output parameter
(→  104).
The Frequency option is
selected in the Operating
mode parameter (→  101)
and a process variable is
selected in the Assign
frequency output parameter
(→  104).
Description
Select process variable for
frequency output.
Enter minimum frequency.
Enter maximum frequency.
Proline Promass H 300 PROFINET
Selection / User
Factory setting
interface / User
entry
• Off
Off
• Mass flow
• Volume flow
• Corrected volume
flow
*
• Target mass flow
*
• Carrier mass flow
• Target volume
*
flow
• Carrier volume
*
flow
• Target corrected
*
volume flow
• Carrier corrected
*
volume flow
• Density
• Reference density
*
• Concentration
• Temperature
• Carrier pipe
*
temperature
• Electronic
temperature
• Oscillation
frequency 0
• Oscillation
*
amplitude 0
• Frequency
*
fluctuation 0
• Oscillation
*
damping 0
• Oscillation
damping
*
fluctuation 0
*
• Signal asymmetry
*
• Exciter current 0
*
• HBSI
• Pressure
• Application
*
specific output 0
• Application
*
specific output 1
• Index
inhomogeneous
medium
• Index suspended
*
bubbles
0.0 to 10 000.0 Hz
0.0 Hz
0.0 to 10 000.0 Hz
10 000.0 Hz
Endress+Hauser