Proline Promass H 300 PROFINET
Parameter
Assign current output 1 to n
Current span
0/4 mA value
Endress+Hauser
Prerequisite
–
–
In the Current span parameter
(→ 99), one of the
following options is selected:
• 4...20 mA NAMUR
(3.8...20.5 mA)
• 4...20 mA US (3.9...20.8
mA)
• 4...20 mA (4... 20.5 mA)
• 0...20 mA (0... 20.5 mA)
Description
Select process variable for
current output.
Select current range for
process value output and
upper/lower level for alarm
signal.
Enter 4 mA value.
Commissioning
User interface /
Factory setting
Selection / User
entry
*
• Off
Mass flow
• Mass flow
• Volume flow
• Corrected volume
*
flow
*
• Target mass flow
*
• Carrier mass flow
• Target volume
*
flow
• Carrier volume
*
flow
• Target corrected
*
volume flow
• Carrier corrected
*
volume flow
• Density
*
• Reference density
*
• Concentration
• Temperature
• Carrier pipe
*
temperature
• Electronic
temperature
• Oscillation
frequency 0
• Oscillation
*
amplitude 0
• Frequency
*
fluctuation 0
• Oscillation
*
damping 0
• Oscillation
damping
*
fluctuation 0
*
• Signal asymmetry
*
• Exciter current 0
*
• HBSI
*
• Pressure
• Application
*
specific output 0
• Application
*
specific output 1
• Index
inhomogeneous
medium
• Index suspended
*
bubbles
• 4...20 mA NAMUR
Country-specific:
(3.8...20.5 mA)
• 4...20 mA NAMUR
• 4...20 mA US
(3.8...20.5 mA)
(3.9...20.8 mA)
• 4...20 mA US
• 4...20 mA (4...
(3.9...20.8 mA)
20.5 mA)
• 0...20 mA (0...
20.5 mA)
• Fixed current
Signed floating-point
Country-specific:
number
• 0 kg/h
• 0 lb/min
99