Auxiliary flow filter (6)
The hydraulic oil change is omitted on
A
use of an auxiliary flow filter!
The quality of the oil must be checked
regularly.
The oil level must be topped up
if necessary!
Replacing filter element:
- Release the threaded cover connection (A) then open the non-return valve briefly
to lower the oil level in the filter, then close the non-return valve again.
- Replace filter element (B) and sealing
ring (C):
- Turn filter element clockwise with the
help of carrier straps and, at the
same time, raise it slightly.
- Wait for a moment until the oil has
escaped downwards, then remove
the filter element.
- Check inlet and outlet in filter hous-
ing (D).
- As required, top up hydraulic oil level
in filter housing then screw down the
cover.
- Bleed the hydraulic system.
m
Do not remove the cardboard sleeve
from the filter element! This is part of the
filter!
F 60.18 16