Fayat Group DYNAPAC SD1800C Manual page 267

Table of Contents

Advertisement

KWP
SPN
FMI
133
9
134
9
135
9
140
9
141
9
142
9
1158
0
1164
1
1159
0
1165
1
1160
0
1166
1
1161
0
1167
1
1162
0
Code
Error Identification
7-6-6
Timeout Error (BAM to packet) for CAN-
Receive-Frame AT1IGCVol1 informa-
tion; factors & Sensorcalibration for NOX
Sensor (SCR-system upstream cat;
DPF- system downstream cat)
7-6-6
Timeout Error (BAM to BAM) for CAN-
Receive-Frame AT1IGCVol1 informa-
tion; factors & Sensorcalibration for NOX
Sensor (SCR-system upstream cat;
DPF- system downstream cat)
7-6-6
Timeout Error (PCK2PCK) for CAN-
Receive-Frame AT1IGCVol1 informa-
tion; factors
& Sensorcalibration for NOX Sensor
(SCR-system upstream cat; DPF-system
downstream cat)
7-6-7
Timeout Error (BAM to packet) for CAN-
Receive-Frame AT1OGCVol2 informa-
tion; factors & Sensorcalibration for NOX
Sensor (SCR-system downstream cat;
DPF- system downstream cat)
7-6-7
Timeout Error (BAM to BAM) for CAN-
Receive-Frame AT1OGCVol2 informa-
tion; factors & Sensorcalibration for NOX
Sensor (SCR-system downstream cat;
DPF- system downstream cat)
7-6-7
Timeout Error (PCK2PCK) for CAN-
Receive-Frame AT1OGCVol2 informa-
tion; factors & Sensorcalibration for NOX
Sensor (SCR-system downstream cat;
DPF- system downstream cat)
7-7-2
Zerofuel calibration injector 1 (in firing
order); maximum value exceeded
7-7-2
Zerofuel calibration injector 1 (in firing
order); minimum value exceeded
7-7-2
Zerofuel calibration injector 2 (in firing
order); maximum value exceeded
7-7-2
Zerofuel calibration injector 2 (in firing
order); minimum value exceeded
7-7-2
Zerofuel calibration injector 3 (in firing
order); maximum value exceeded
7-7-2
Zerofuel calibration injector 3 (in firing
order); minimum value exceeded
7-7-2
Zerofuel calibration injector 4 (in firing
order); maximum value exceeded
7-7-2
Zerofuel calibration injector 4 (in firing
order); minimum value exceeded
7-7-2
Zerofuel calibration injector 5 (in firing
order); maximum value exceeded
Short Text Detail
Timeout Error (BAM to packet) for CAN-
Receive-Frame AT1IGCVol1 information; fac-
tors & Sensorcalibration for NOX Sensor (SCR-
system upstream cat; DPF-system down-
stream cat)
Timeout Error (BAM to BAM) for CAN-Receive-
Frame AT1IGCVol1 information; factors & Sen-
sorcalibration for NOX Sensor (SCR-system
upstream cat; DPF-system downstream cat)
Timeout Error (PCK2PCK) for CAN-Receive-
Frame AT1IGCVol1 information; factors & Sen-
sorcalibration for NOX Sensor (SCR-system
upstream cat; DPF-system downstream cat)
Timeout Error (BAM to packet) for CAN-
Receive-Frame AT1OGCVol2 information; fac-
tors & Sensorcalibration for NOX Sensor (SCR-
system downstream cat; DPF-system down-
stream cat)
Timeout Error (BAM to BAM) for CAN-Receive-
Frame AT1OGCVol2 information; factors &
Sensorcalibration for NOX Sensor (SCR-sys-
tem downstream cat; DPF-system downstream
cat)
Timeout Error (PCK2PCK) for CAN-Receive-
Frame AT1OGCVol2 information; factors &
Sensorcalibration for NOX Sensor (SCR-sys-
tem downstream cat; DPF-system downstream
cat)
Zerofuel calibration injector 1 (in firing order);
maximum value exceeded
Zerofuel calibration injector 1 (in firing order);
minimum value exceeded
Zerofuel calibration injector 2 (in firing order);
maximum value exceeded
Zerofuel calibration injector 2 (in firing order);
minimum value exceeded
Zerofuel calibration injector 3 (in firing order);
maximum value exceeded
Zerofuel calibration injector 3 (in firing order);
minimum value exceeded
Zerofuel calibration injector 4 (in firing order);
maximum value exceeded
Zerofuel calibration injector 4 (in firing order);
minimum value exceeded
Zerofuel calibration injector 5 (in firing order);
maximum value exceeded
D 23.18 103

Advertisement

Table of Contents
loading

This manual is also suitable for:

911

Table of Contents