Fayat Group DYNAPAC SD1800C Manual page 257

Table of Contents

Advertisement

KWP
SPN
FMI
839
4
843
2
841
3
842
4
846
2
844
3
845
4
826
2
827
2
876
7
831
11
832
11
828
12
829
12
830
14
980
12
948
13
462
0
463
0
126
9
300
9
301
9
387
12
Code
Error Identification
1-4-3
Multiple Stage Switch constant speed;
short circuit to ground
1-4-3
Multiple Stage Switch engine speed con-
trol parameter; plausibility error
1-4-3
Multiple Stage Switch engine speed con-
trol parameter; short circuit to battery
1-4-3
Multiple Stage Switch engine speed con-
trol parameter; short circuit to ground
1-4-3
Multiple Stage Switch engine torque limi-
tation curve; plausibility error
1-4-3
Multiple Stage Switch engine torque limi-
tation curve; short circuit to battery
1-4-3
Multiple Stage Switch engine torque limi-
tation curve; short circuit to ground
1-4-6
Pressure Relief Valve (PRV) forced to
open
1-4-6
Pressure Relief Valve (PRV) forced to
open
1-4-6
Maximum rail pressure in limp home
mode exceeded (PRV)
1-4-6
Pressure Relief Valve (PRV) error; Rail
pressure out of tolerance range
1-4-6
Rail pressure out of tolerance range
1-4-6
Pressure Relief Valve (PRV) forced to
open; system reaction initiated
1-4-6
Pressure Relief Valve (PRV) forced to
open; system reaction initiated
1-4-6
Pressure Relief Valve (PRV) is open
5-1-5
T50 start switch active for too long
2-8-2
Sensor supply voltage monitor 3 error
(ECU)
2-2-8
Fan control; out of range, system reac-
tion initiated
2-2-8
Fan control; out of range, system reac-
tion initiated
3-3-8
Timeout Error of CAN-Receive-Frame
AMB; Ambient Temperature Sensor
1-1-8
Timeout Error of CAN-Receive-Frame
TSC1AE; Traction Control
1-1-9
Timeout Error of CAN-Receive-Frame
TSC1AR; Retarder
5-5-5
Internal software error ECU
Short Text Detail
Multiple Stage Switch constant speed; short
circuit to ground
Multiple Stage Switch engine speed control
parameter; plausibility error
Multiple Stage Switch engine speed control
parameter; short circuit to battery
Multiple Stage Switch engine speed control
parameter; short circuit to ground
Multiple Stage Switch engine torque limitation
curve; plausibility error
Multiple Stage Switch engine torque limitation
curve; short circuit to battery
Multiple Stage Switch engine torque limitation
curve; short circuit to ground
Pressure Relief Valve (PRV) forced to open;
performed by pressure increase
Pressure Relief Valve (PRV) forced to open;
performed by pressure shock
Maximum rail pressure in limp home mode
exceeded (PRV)
The PRV can not be opened at this operating
point with a pressure shock
Rail pressure out of tolerance range
Open Pressure Relief Valve (PRV); shut off
condition
Open Pressure Relief Valve (PRV); warning
condition
Pressure Relief Valve (PRV) is open
T50 start switch active for too long
Sensor supply voltage monitor 3 error (ECU)
High fan speed; warning threshold exceeded
High fan speed; shut off threshold exceeded
Timeout Error of CAN-Receive-Frame AMB;
Ambient Temperature Sensor
Timeout Error of CAN-Receive-Frame
TSC1AE; Traction Control
Timeout Error of CAN-Receive-Frame
TSC1AR; Retarder
Internal software error ECU; injection cut off
D 23.18 93

Advertisement

Table of Contents
loading

This manual is also suitable for:

911

Table of Contents