Fayat Group DYNAPAC SD1800C Manual page 237

Table of Contents

Advertisement

KWP
SPN
FMI
1400
1136
3
1401
1136
4
1402
4769
2
1403
4769
2
1404
3248
2
1405
3248
0
1406
3248
0
1407
3248
0
1408
3248
1
1409
3248
1
1410
3248
1
1411
1188
11
1412
1188
11
1413
1188
13
1414
1188
2
1415
1188
7
1416
1188
11
1417
1188
11
1418
1188
11
1419
524011
0
Code
Error Identification
6-8-1
Sensor error ECU temperature; signal
range check high
6-8-1
Sensor error ECU temperature; signal
range check low
6-8-4
Sensor exhaust gas temperature (DOC)
downstream; plausibility error
6-8-4
Sensor exhaust gas temperature (DOC)
downstream; plausibility error
6-8-5
Sensor exhaust gas temperature down-
stream DPF; plausibility error
6-8-5
Exhaust gas temperature particulate filter
downstream; out of range, system reac-
tion initiated
6-8-5
Exhaust gas temperature particulate filter
downstream; out of range, system reac-
tion initiated
6-8-5
Exhaust gas temperature particulate filter
downstream; out of range, system reac-
tion initiated
6-8-5
Exhaust gas temperature particulate filter
downstream; out of range, system reac-
tion initiated
6-8-5
Exhaust gas temperature particulate filter
downstream; out of range, system reac-
tion initiated
6-8-5
Exhaust gas temperature particulate filter
downstream; out of range, system reac-
tion initiated
8-1-4
Turbo charger wastegate actuator; inter-
nal error
8-1-4
Turbo charger wastegate actuator; inter-
nal error
8-1-4
Wastegate actuator calibration deviation
too large, recalibration required
8-1-4
Wastegate; status message from ECU
missing
8-1-4
Wastegate actuator; blocked
8-1-4
Turbo charger wastegate actuator; inter-
nal error
8-1-4
Turbo charger wastegate actuator; inter-
nal error
8-1-4
Turbo charger wastegate actuator; inter-
nal error
7-7-2
Zerofuel calibration injector 7 (in firing
order); maximum value exceeded
Short Text Detail
Sensor error ECU temperature; signal range
check high
Sensor error ECU temperature; signal range
check low
Sensor exhaust gas temperature OxiCat down-
stream (normal operation); plausibility error
Sensor exhaust gas temperature OxiCat down-
stream (regeneration); plausibility error
Sensor exhaust gas temperature downstream
DPF; plausibility error
Physical range check high for exhaust gas tem-
perature particulate filter downstream
Physical range check high for exhaust gas tem-
perature particulate filter downstream; shut off
regeneration
Physical range check high for exhaust gas tem-
perature particulate filter downstream; warning
Physical range check low for exhaust gas tem-
perature particulate filter downstream
Physikal range check low for exhaust gas tem-
perature particulate filter downstream; shut off
regeneration
Physical range check low for exhaust gas tem-
perature particulate filter downstream; warning
Wastegate actuator; internal error
Wastegate actuator; EOL calibration not per-
formed correctly
Wastegate actuator calibration deviation too
large, recalibration required
Wastegate; status message from ECU missing
Wastegate actuator; blocked
Wastegate actuator; over temperature (>
145°C)
Wastegate actuator; over temperature (>
135°C)
Wastegate actuator; operating voltage error
Zerofuel calibration injector 7 (in firing order);
maximum value exceeded
D 23.18 73

Advertisement

Table of Contents
loading

This manual is also suitable for:

911

Table of Contents