Fayat Group DYNAPAC SD1800C Manual page 247

Table of Contents

Advertisement

KWP
SPN
FMI
796
4
793
11
1009
2
1007
3
1008
4
306
9
49
2
971
3
972
4
969
5
970
12
376
12
377
12
378
12
84
14
580
3
586
4
568
5
581
3
587
4
569
5
582
3
588
4
570
5
583
3
589
4
Code
Error Identification
6-9-3
Sensor error differential pressure Ventu-
riunit (EGR); signal range check low
6-9-3
Sensor differential pressure Venturiunit
(EGR); plausibility error
6-8-2
Sensor exhaust gas temperature Ventu-
riunit (EGR); plausibility error
6-8-2
Sensor error EGR cooler downstream
temperature; signal range check high
6-8-2
Sensor error EGR cooler downstream
temperature; signal range check low
1-1-9
Timeout Error of CAN-Receive-Frame
TSC1TR; Setpoint
3-2-1
Break lever mainswitch and break lever
redundancyswitch status not plausible
5-1-3
SVS lamp; short circuit to battery
5-1-3
SVS lamp; short circuit to ground
5-1-3
SVS lamp; open load
5-1-3
SVS lamp; powerstage over temperature
2-8-1
Access error EEPROM
2-8-1
Access error EEPROM
2-8-1
Access error EEPROM
2-7-1
CAN-Bus 0 "BusOff-Status"
1-5-4
Injector 1 (in firing order); short circuit
1-5-4
High side to low side short circuit in the
injector 1 (in firing order)
1-5-4
Injector 1 (in firing order); interruption of
electric connection
1-5-5
Injector 2 (in firing order); short circuit
1-5-5
High side to low side short circuit in the
injector 2 (in firing order)
1-5-5
Injector 2 (in firing order); interruption of
electric connection
1-5-6
Injector 3 (in firing order); short circuit
1-5-6
High side to low side short circuit in the
injector 3 (in firing order)
1-5-6
Injector 3 (in firing order); interruption of
electric connection
1-6-1
Injector 4 (in firing order); short circuit
1-6-1
High side to low side short circuit in the
injector 4 (in firing order)
Short Text Detail
Sensor error differential pressure Venturiunit
(EGR); signal range check low
Sensor differential pressure Venturiunit (EGR);
plausibility error
Sensor exhaust gas temperature Venturiunit
(EGR); plausibility error
Sensor error EGR cooler downstream temper-
ature; signal range check high
Sensor error EGR cooler downstream temper-
ature; signal range check low
Timeout Error of CAN-Receive-Frame
TSC1TR; Setpoint
Break lever mainswitch and break lever redun-
dancyswitch status not plausible
SVS lamp; short circuit to battery
SVS lamp; short circuit to ground
SVS lamp; open load
SVS lamp; powerstage over temperature
Access error EEPROM memory (delete)
Access error EEPROM memory (read)
Access error EEPROM memory (write)
CAN-Bus 0 "BusOff-Status"
Injector 1 (in firing order); short circuit
High side to low side short circuit in the injector
1 (in firing order)
Injector 1 (in firing order); interruption of electric
connection
Injector 2 (in firing order); short circuit
High side to low side short circuit in the injector
2 (in firing order)
Injector 2 (in firing order); interruption of electric
connection
Injector 3 (in firing order); short circuit
High side to low side short circuit in the injector
3 (in firing order)
Injector 3 (in firing order); interruption of electric
connection
Injector 4 (in firing order); short circuit
High side to low side short circuit in the injector
4 (in firing order)
D 23.18 83