Fayat Group DYNAPAC SD1800C Manual page 239

Table of Contents

Advertisement

KWP
SPN
FMI
1458
523960
0
1459
523960
1
1460
1180
0
1461
1180
1
1462
1180
0
1463
1180
1
1474
524037
5
1475
84
2
1477
524037
3
1478
524037
4
1479
524062
12
1480
524062
12
1481
524025
5
1482
524044
9
1483
523632
2
1484
524068
2
1485
524052
11
1486
523718
5
1487
523718
12
1488
523718
3
1489
523718
4
1490
4376
5
1491
4376
12
Code
Error Identification
7-7-1
Exhaust gas temperature EGR down-
stream; out of range, system reaction ini-
tiated
7-7-1
Exhaust gas temperature EGR down-
stream; out of range, system reaction ini-
tiated
8-1-4
Exhaust gas temperature turbine
upstream; out of range, system reaction
initiated
8-1-4
Exhaust gas temperature turbine
upstream; out of range, system reaction
initiated
5-5-6
Exhaust gas temperature turbine
upstream; out of range, system reaction
initiated
5-5-6
Exhaust gas temperature turbine
upstream; out of range, system reaction
initiated
Ashlamp; open load
5-2-1
Sensor vehicle speed; plausibility error
Ashlamp; short circuit to battery
Ashlamp; short circuit to ground
EAT-system HMI disrupted
EAT-system HMI disrupted
DPF system; operating voltage error
CAN message ComMS_Sys7 not
received from slave
Metering control is not performed in time
error
Master ECU and Slave ECU have been
identified as the same types
MS ECU reported internal error
SCR mainrelay; open load (only CV56B)
SCR mainrelay; powerstage over tem-
perature (only CV56B)
SCR mainrelay; short circuit to battery
(only CV56B)
SCR mainrelay; short circuit to ground
(only CV56B)
6-6-7
SCR reversing valve; open load
6-6-7
SCR reversing valve; over temperature
Short Text Detail
High exhaust gas temperature EGR cooler
downstream; warning threshold exceeded
High exhaust gas temperature EGR cooler
downstream; shut off threshold exceeded
Turbocharger Wastegate CAN feedback; warn-
ing threshold exceeded
Turbocharger Wastegate CAN feedback; shut
off threshold exceeded
Exhaust gas temperature upstream turbine;
warning threshold exceeded
Exhaust gas temperature upstream turbine;
shut off threshold exceeded
Ashlamp; open load
Sensor vehicle speed; plausibility error
Ashlamp; short circuit to battery
Ashlamp; short circuit to ground
Regeneration inhibit switch not available; Com-
InhSwtNA
Regeneration release switch not available;
ComRegSwtNA
DPF system; operating voltage error
CAN message ComMS_Sys7 not received
from slave
Metering control is not performed in time error
Master ECU and Slave ECU have been identi-
fied as the same types
Master ECU and Slave ECU data sets or soft-
ware are not identical
SCR mainrelay; open load (only CV56B)
SCR mainrelay; powerstage over temperature
(only CV56B)
SCR mainrelay; short circuit to battery (only
CV56B)
SCR mainrelay; short circuit to ground (only
CV56B)
SCR reversing valve; open load
SCR reversing valve; over temperature
D 23.18 75