Fayat Group DYNAPAC SD1800C Manual page 211

Table of Contents

Advertisement

KWP
SPN
FMI
60
523911
3
61
523911
3
62
523911
4
63
523911
11
64
523912
2
66
523912
0
69
523912
1
72
523912
3
73
523912
4
74
523913
3
75
523913
4
76
523914
5
77
523914
12
78
523914
3
79
523914
4
82
1235
14
84
639
14
85
1231
14
86
1235
14
88
102
2
89
102
2
96
110
3
Code
Error Identification
7-2-3
Burner dosing valve (DV2); short circuit
to battery
7-2-3
Burner dosing valve (DV2); short circuit
to battery
7-2-3
Burner dosing valve (DV2); short circuit
to ground
7-2-3
Burner dosing valve (DV2); short circuit
high side powerstage
7-2-2
Burner dosing valve (DV2) downstream
pressure sensor; plausibility error
7-2-2
Physical range check high for burner
dosing valve (DV2) downstream pres-
sure; shut off regeneration
7-2-2
Physical range check low for burner dos-
ing valve (DV2) downstream pressure;
shut off regeneration. When burner injec-
tor is actuated, the measured pressure
does not rise above ca. 1250mbar abs
(expected: ca. 2400mbar).
7-2-2
Sensor error burner dosing valve (DV2)
downstream pressure sensor; signal
range check high
7-2-2
Sensor error burner dosing valve (DV2)
downstream pressure sensor; signal
range check low
7-2-1
Sensor error glow plug control diagnostic
line voltage; signal range check high
7-2-1
Sensor error glow plug control diagnostic
line voltage; signal range check low
7-2-1
Glow plug control; open load
7-2-1
Glow plug control; powerstage over tem-
perature
7-2-1
Glow plug control; short circuit to battery
7-2-1
Glow plug control; short circuit to ground
2-7-1
CAN Bus error passive; warning CAN C
2-7-1
CAN-Bus 0 "BusOff-Status"
2-7-1
CAN-Bus 1 "BusOff-Status"
2-7-1
CAN-Bus 2 "BusOff-Status"
2-2-3
Charged air pressure; system reaction
initiated
2-2-3
Charged air pressure; system reaction
initiated
2-2-5
Sensor error coolant temperature; signal
range check high
Short Text Detail
Burner dosing valve (DV2); short circuit to bat-
tery
Burner dosing valve (DV2); short circuit to bat-
tery on high side
Burner dosing valve (DV2); short circuit to
ground
Burner dosing valve (DV2); short circuit high
side powerstage
Burner dosing valve (DV2) downstream pres-
sure sensor; plausibility error
Physical range check high for burner dosing
valve (DV2) downstream pressure; shut off
regeneration
Physical range check low for burner dosing
valve (DV2) downstream pressure; shut off
regeneration. When burner injector is actuated,
the measured pressure does not rise above ca.
1250mbar abs (expected: ca. 2400mbar).
Sensor error burner dosing valve (DV2) down-
stream pressure sensor; signal range check
high
Sensor error burner dosing valve (DV2) down-
stream pressure sensor; signal range check
low
Sensor error glow plug control diagnostic line
voltage; signal range check high
Sensor error glow plug control diagnostic line
voltage; signal range check low
Glow plug control; open load
Glow plug control; powerstage over tempera-
ture
Glow plug control; short circuit to battery
Glow plug control; short circuit to ground
CAN Bus error passive; warning CAN C
CAN-Bus 0 "BusOff-Status"
CAN-Bus 1 "BusOff-Status"
CAN-Bus 2 "BusOff-Status"
Charged air pressure above warning threshold
Charged air pressure above shut off threshold
Sensor error coolant temperature; signal range
check high
D 23.18 47

Advertisement

Table of Contents
loading

This manual is also suitable for:

911