Fayat Group DYNAPAC SD1800C Manual page 311

Table of Contents

Advertisement

Installation and operation
CAUTION
CAUTION
- Install the bracket (1) at the vehicle step (3) using the corresponding assembly ma-
terial (2).
- Fasten the illuminated balloon (4) to the holding tube (5) and tighten the clamping
bolt (6).
- Guide the holding tube (5) into the premounted holder (1) and tighten the clamping
lever (7) correctly to fix the holding tube.
- With one hand on the handle flagged in green (8), pull down hard to open the bal-
loon before putting it into operation.
When the balloon has been pulled down completely as far as it will go, a safety
brace (9) hinges out of the guide rod.
- Once the illuminated balloon is completely mounted and secured, connect
the plug (10) of the illuminated balloon in the corresponding switch cabinet
sockets (11).
Never adjust the holding tube while the illuminated balloon is in operation.
m
Operation of the switch cabinet - see screed operating instructions.
A
Route the supply lines so as to rule out any risk of stumbling or damage to the lines.
m
Danger due to electric shock
Electric shock can cause severe or fatal injuries
- The Powermoon must always be completely unpacked,
assembled and aligned before it is connected to the
power grid and switched on!
Danger of squeezing!
Fingers or hands can get clamped between the bracket and
the holding tube!
- Caution when inserting the holding tube!
D 30.18 37