Fayat Group DYNAPAC SD1800C Manual page 265

Table of Contents

Advertisement

KWP
SPN
FMI
765
0
768
1
763
2
1379
2
770
3
771
4
986
0
989
1
1395
2
942
3
944
4
984
11
965
3
967
4
1392
4
963
5
1389
5
1262
7
1264
7
1192
12
1390
12
36
3
37
3
Code
Error Identification
7-1-6
Physical range check high for exhaust-
gas back pressure burner; shut off
regeneration
7-1-6
Physical range check low for exhaustgas
back pressure burner; shut off regenera-
tion
7-1-6
Sensor exhaustgas back pressure; plau-
sibility error
7-1-6
Sensor exhaustgas back pressure; plau-
sibility error
7-1-6
Sensor error exhaustgas back pressure
burner; signal range check high
7-1-6
Sensor error exhaustgas back pressure
burner; signal range check low
7-1-4
Physical range check high for burner
temperature
7-1-4
Physical range check low for burner tem-
perature
7-1-4
Sensor burner temperature; plausibility
error
7-1-4
Sensor error burner temperature; signal
range check high
7-1-4
Sensor error burner temperature; signal
range check low
7-1-4
Sensor burner temperature; plausibility
error
7-1-5
Burner shut of valve; short circuit to bat-
tery
7-1-5
Burner shut of valve; short circuit to
ground
7-1-5
Burner shut of valve; short circuit to
ground
7-1-5
Burner shut off valve; open load
7-1-5
Burner Shut Off Valve; open load
8-5-4
Shut off valve: blocked
8-5-5
Shut off valve: blocked
Over temperature error on burner shut of
valve
7-1-5
Over temperature error on burner shut of
valve
7-2-9
UB1; Short circuit to battery error of actu-
ator relay 1
7-3-0
UB2; Short circuit to battery error of actu-
ator relay 2
Short Text Detail
Physical range check high for exhaustgas back
pressure burner; shut off regeneration
Physical range check low for exhaustgas back
pressure burner; shut off regeneration
Sensor exhaustgas back pressure; plausibility
error
Sensor exhaust gas back pressure burner;
plausibility error
Sensor error exhaustgas back pressure burner;
signal range check high
Sensor error exhaustgas back pressure burner;
signal range check low
Physical range check high for burner tempera-
ture
Physical range check low for burner tempera-
ture
Sensor burner temperature; plausibility error
Sensor error burner temperature; signal range
check high
Sensor error burner temperature; signal range
check low
Sensor burner temperature; plausibility error
Burner shut of valve; short circuit to battery
Burner shut of valve; short circuit to ground
Burner Shut Off Valve; short circuit to ground
Burner shut off valve; open load
Burner Shut Off Valve; open load
Burner Shut Off Valve; blocked closed
Burner Shut Off Valve; blocked open
Over temperature error on burner shut of valve
Burner Shut Off Valve; powerstage over tem-
perature
UB1; Short circuit to battery error of actuator
relay 1
UB2; Short circuit to battery error of actuator
relay 2
D 23.18 101

Advertisement

Table of Contents
loading

This manual is also suitable for:

911

Table of Contents