Fayat Group DYNAPAC SD1800C Manual page 259

Table of Contents

Advertisement

KWP
SPN
FMI
860
0
862
0
861
1
864
2
594
3
596
3
595
4
597
4
592
5
593
12
488
2
899
0
900
1
1483
2
897
16
898
18
881
11
882
11
883
11
122
11
125
12
1100
3
1488
3
Code
Error Identification
1-3-4
Rail pressure disrupted
1-3-4
Rail pressure disrupted
1-3-4
Minimum rail pressure exceeded
(RailMeUn3)
1-3-4
Setpoint of metering unit in overrun
mode not plausible
1-3-5
Metering unit (Fuel-System); short cir-
cuit to battery
1-3-5
Metering unit (Fuel-System); short cir-
cuit to battery
1-3-5
Metering unit (Fuel-System); short cir-
cuit to ground
1-3-5
Metering unit (Fuel-System); short cir-
cuit to ground
1-3-5
Metering unit (Fuel-System); open load
1-3-5
Metering unit (Fuel-System); powerstage
over temperature
1-3-3
Physical range check high for exhaust
gas temperature upstrem (SCR-CAT)
8-7-7
Pressure overload of SCR-System
8-7-8
Pressure build-up error SCR-System
Metering control is not performed in time
error
8-7-5
Pump pressure SCR metering unit too
high
8-7-6
Pump pressure SCR metering unit too
low
7-0-1
Nox conversion rate insufficient
7-0-1
Nox conversion rate insufficient
7-0-1
Nox conversion rate insufficient
5-9-2
Shut off request from supervisory moni-
toring function
5-9-5
Timeout Error of CAN-Transmit-Frame
AmbCon; Weather environments
6-7-6
SCR main relay (primary side); short cir-
cuit to battery
SCR mainrelay; short circuit to battery
(only CV56B)
Short Text Detail
Negative deviation of rail pressure second
stage (RailMeUn22)
Maximum rail pressure exceeded (RailMeUn4)
Minimum rail pressure exceeded (RailMeUn3)
Setpoint of metering unit in overrun mode not
plausible
Metering unit (Fuel-System); short circuit to
battery highside
Metering unit (Fuel-System); short circuit to
battery low side
Metering unit (Fuel-System); short circuit to
ground high side
Metering Unit (Fuel-System); short circuit to
ground low side
Metering unit (Fuel-System); open load
Metering unit (Fuel-System); powerstage over
temperature
Physical range check high for exhaust gas tem-
perature upstrem (SCR-CAT)
Pressure overload of SCR-System
Pressure build-up error SCR-System
Metering control is not performed in time error
Pump pressure SCR metering unit too high
Pump pressure SCR metering unit too low
Nox conversion rate insufficient (SCR-Cat
defect, bad AdBule quality)
Nox conversion rate insufficient (SCR-Cat
defect, bad AdBule quality); temperature range
1
Nox conversion rate insufficient (SCR-Cat
defect, bad AdBule quality); temperature range
2
Shut off request from supervisory monitoring
function
Timeout Error of CAN-Transmit-Frame Amb-
Con; Weather environments
SCR main relay (primary side); short circuit to
battery
SCR mainrelay; short circuit to battery (only
CV56B)
D 23.18 95