Fayat Group DYNAPAC SD1800C Manual page 236

Table of Contents

Advertisement

KWP
SPN
FMI
1337
2797
4
1338
2798
4
1339
2798
4
1340
2798
4
1341
524035
12
1342
524036
12
1343
524004
12
1344
524005
12
1345
524069
9
1357
524052
11
1368
524052
11
1378
523919
2
1379
523920
2
1380
3253
2
1381
164
2
1389
523922
5
1390
523922
12
1392
523922
4
1395
523921
2
1398
1136
0
1399
1136
1
D 23.18 72
Code
Error Identification
Injector diagnostics; timeout error of
short circuit to ground measurement cyl.
Bank 0
Injector diagnostics; timeout error of
short circuit to ground measurement cyl.
Bank 1
Injector diagnostics; short circuit Bank 0,
Bank 1
Injector diagnostics; short circuit Bank 0,
Bank 1
5-5-5
Injector diagnostics; time out error in the
SPI communication
Injector diagnostics Slave; time out error
in the SPI communication
8-0-4
Too many recognized misfires in cylinder
7 (in firing order)
8-0-5
Too many recognized misfires in cylinder
8 (in firing order)
Timeout Error of CAN-Receive-Frame
MSMon_FidFCCTO; Master-Slave CAN
communication faulty
MS ECU reported internal error
MS ECU reported internal error
6-9-4
Sensor airpump pressure; plausibility
error
7-1-6
Sensor exhaustgas back pressure; plau-
sibility error
6-9-2
Sensor differential pressure (DPF); plau-
sibility error
8-3-9
Rail pressure safety function is not exe-
cuted correctly
7-1-5
Burner Shut Off Valve; open load
7-1-5
Over temperature error on burner shut of
valve
7-1-5
Burner shut of valve; short circuit to
ground
7-1-4
Sensor burner temperature; plausibility
error
6-8-1
Physikal range check high for ECU tem-
perature
6-8-1
Physikal range check low for ECU tem-
perature
Short Text Detail
Injector diagnostics; timeout error of short cir-
cuit to ground measurement cyl. Bank 0
Injector diagnostics; timeout error of short cir-
cuit to ground measurement cyl. Bank 1
Injector diagnostics; short circuit to ground
monitoring Test in Cyl. Bank 0
Injector diagnostics; short circuit to ground
monitoring Test in Cyl. Bank 1
Injector diagnostics; time out error in the SPI
communication
Injector diagnostics Slave; time out error in the
SPI communication
Too many recognized misfires in cylinder 7 (in
firing order)
Too many recognized misfires in cylinder 8 (in
firing order)
Timeout Error of CAN-Receive-Frame
MSMon_FidFCCTO; Master-Slave CAN com-
munication faulty
Error memory Slave reports FID MSMonFC2;
Shut-Off Path test error of fuel injection system
Error memory Slave reports FID MSMonFC3;
timeout of engine state messages
(ComMS_Sys1-
7) from master ECU
Sensor air pump airpressure; plausibility error
Sensor exhaust gas back pressure burner;
plausibility error
Sensor differential pressure (DPF); plausibility
error
Rail pressure safety function is not executed
correctly
Burner Shut Off Valve; open load
Burner Shut Off Valve; powerstage over tem-
perature
Burner Shut Off Valve; short circuit to ground
Sensor burner temperature; plausibility error
Physikal range check high for ECU tempera-
ture
Physikal range check low for ECU temperature

Advertisement

Table of Contents
loading

This manual is also suitable for:

911

Table of Contents