Graco HORIZON Instructions-Parts List Manual page 49

Fluid management systems
Table of Contents

Advertisement

Horizon System Components
Solenoid Cable (bulk)
These cables connect the air and fluid solenoids to the
control modules. They are 2-conductor, 18 AWG
unshielded cables and are available in bulk spools of
500 or 1000 ft. (152.5 or 305 m). Solenoids can be no
further than 50 ft. (15.3 m) from a control module.
Control
Module
Keypad
Printer
Computer
Control
Module
Network Cable (bulk)
Control modules are linked together with 2-conductor,
22 AWG shielded cable, which is available in bulk
spools of 500 or 1000 ft. (152.5 or 305 m). There is no
distance requirement between control modules, pro -
vided the overall length of the network is not greater
than 2000 ft. (610 m).
Cables
2000 ft. (610 m) maximum total network length
Control
Bulk Cable, P/N 113–559 [500 ft. (152.5 m)] or
Module
113–560 [1000 ft. (305 m)]
Bulk Cable, P/N 113–557 [500 ft. (152.5 m)] or
113–558 [1000 ft. (305 m)]
50 ft. (15.3 m) maximum total length
Bulk Cable, P/N 113–555 [500 ft. (152.5 m)] or
113–556 [1000 ft. (305 m)]
Cable with connector, P/N 191–393 [25 ft. (7.6
m)] or 191–394 [50 ft. (15.3 m)]
Cable with connector, P/N 191–395 [25 ft. (7.6
Solenoid
m)] or 191–396 [50 ft. (15.3 m)]
Meter
308–607
49