Horizon System Components
Fluid Solenoid Valves
Part No. 218–588, Fluid Solenoid Valve
0 to 3 gpm (0–11.4 liter/min.), with Ready Light; See
manual 307–696 for more information
Part No. 215–487, Fluid Solenoid Valve
0 to 3 gpm (0–11.4 liter/min.), without Ready Light; See
manual 307–696 for more information
Part No. 512–927, Fluid Solenoid Valve
0 to 6 gpm (0–22.7 liter/min.), without Ready Light
Part No. 238–996, Ready Light Kit
T echnical Data
Category
Type
Electrical Rating
Coil Insulation
Leads
Maximum Working
Pressure
Inlet/Outlet
Minimum Actuation Volts
Required
Wiring Gauge Required
(by cable length)
Part No. 215–487 shown
Fluid Solenoid
46
308–607
Data
2 way, normally closed
28 V DC, 0.46 amp
NOTE: provides minimum
current draw when operated at
24 V DC
Class H
18 AWG x 18.0 in. (457 mm)
long
3000 psi (21 MPa, 207 bar)
1/2 npt
20
18 AWG up to 50 ft. (15.3 m)
IN
Air Solenoid Valves
Part No. 215–407, Air Solenoid Valve; Low Flow
For low-air-flow requirement pump models, such as the
Eagle
and Fire-Ball
Part No. 512–926, Air Solenoid Valve; High Flow
For higher-flow pump models, such as the President
T echnical Data
Category
Type
Electrical Rating
Coil Insulation
Leads
Inlet/Outlet
Part No. 215–407
Part No. 512–926
Wiring Gauge Required
(by cable length)
Part No. 215–407 shown
EXHAUST
3
2
1
OUT
IN
Air Solenoid
Fluid and Air Solenoids
Solenoids are electrically operated by the control
module they are connected to. The fluid solenoids start
and stop the fluid dispense cycles. The air solenoids
open and close the air supply to the pump.
Solenoid Specifications:
Up to 6 solenoids can be connected to each control
module.
A fluid solenoid must be placed at each dispense
point for each fluid being dispensed.
The use of air solenoids to turn off pressure to the
pumps when a fluid is not being dispensed is
strongly recommended. Standard thermal/pressure
relief design practices should be followed also.
Data
3 way solenoid operated air
valve, normally closed
24 V DC, 0.25 amps
General purpose, Class A
Encapsulated, Continuous
Duty
18 AWG x 12.0 in. (305 mm)
long
Adapted to 1/2 npt
3/8 npt
18 AWG up to 50 ft. (15.3 m)