Appendix 2 Details Of Remote Registers - Mitsubishi Electric NZ2GFCF-D62PD2 User Manual

Cc-link ie field network high-speed counter module
Table of Contents

Advertisement

Appendix 2
The following shows details of remote registers.
(1) Remote registers (RWr0 to RWr1)
Address
(RWr)
Name
CH1
CH2
Counter value
0
greater/smaller
signal
EQU1 to EQU4
1
terminal status
Details of Remote Registers
• When the coincidence output function is selected and Coincidence output
comparison condition setting (address: 0102
(00)", this area stores the magnitude relation between the values in Point setting
(Coincidence output 1 to 4) (RWw0 to RWw1, RWw4 to RWw5, RWw8 to
RWw9, RWwC to RWwD) and CH Present value (RWr10 to RWr11, RWr28 to
RWr29).
b15
b14
b13
b12
b11
b10
0
0
0
0
0
0
-
-
-
-
-
-
0 (fixed)
Point setting (Coincidence output 1 to 4) > Present value ... Counter value greater:
0/Counter value smaller: 1
Point setting (Coincidence output 1 to 4) = Present value ... Counter value greater:
0/Counter value smaller: 0
Point setting (Coincidence output 1 to 4) < Present value ... Counter value greater:
1/Counter value smaller: 0
• When Initial data setting request flag (RY9) is turned off then on, the value in this
area is cleared.
• This area stores the statuses of the coincidence output 1 to 4 terminals (EQU1
to EQU4).
b15
b14
b13
b12
b11
b10
0
0
0
0
0
0
0 (fixed)
• When Initial data setting request flag (RY9) is turned off then on, the value in this
area is cleared.
Description
) is set to "Coincidence Output
H
b9
b8
b7
b6
b5
b4
b3
Coincidence
Coincidence
Coincidence
0
0
output 3
output 2
output 4
Counter
Counter
Counter
Counter
Counter
-
-
value
value
value
value
value
greater
smaller
greater
smaller
greater
b9
b8
b7
b6
b5
b4
b3
0
0
0
0
0
0
EQU4
APPENDICES
Default
b2
b1
b0
Coincidence
output 1
Counter
Counter
Counter
value
value
value
0000
smaller
greater
smaller
H
b2
b1
b0
EQU3
EQU2
EQU1
0000
H
0: OFF
1: ON
275
A