Remote
output (RY)
Signal name
No.
RY24
CH1
Count enable
RY3C
CH2
command
Selected
RY25
CH1
counter function
RY3D
CH2
start command
Cam switch
execute
RY26
CH1
command/PWM
RY3E
CH2
output start
command
Setting change
request
RY27
CH1
(Sampling
RY3F
CH2
counter/Periodic
pulse counter)
Operation
timing
• Turn on this signal to count pulses.
• The following figure shows the overview of the operation (when 1-Phase
Multiple of 1 (0) is selected for CH1 Pulse input mode (address: 0122
CH1 Count
enable command
CH1 Present value
(RWr10 to RWr11)
• Turn on this signal to perform the selected counter functions.
• When Count Disable Function (0) or Periodic Pulse Counter Function (3) is
selected for CH Counter function selection (address: 0126
signal is valid while being on.
• When Sampling Counter Function (2) or Latch Counter Function (1) is
selected for CH Counter function selection (address: 0126
signal becomes valid at the rising edge (off to on).
• When Count disable/Preset/replace Function (4) or Latch
counter/Preset/replace Function (5) is selected for CH Counter function
selection (address: 0126
the operation, refer to Page 256, Appendix 1.1.)
• Turn on this signal to execute the cam switch function.
• Turn on this signal to start PWM output.
• Turn on this signal to activate the changes of CH Time unit setting
(Sampling counter/Periodic pulse counter) (RWw16, RWw2E) and CH
Cycle setting (Sampling counter/Periodic pulse counter) (RWw17, RWw2F).
• When this signal is turned on, the setting values written into the above remote
registers (RWw) are reflected to the high-speed counter module. After the
setting values are reflected, CH Setting change completed (Sampling
counter/Periodic pulse counter) (RX27, RX3F) turns on. (For the overview of
the operation, refer to Page 256, Appendix 1.1.)
Description
ON
OFF
A
ON
OFF
B
ON
OFF
(RY24)
0
, 0146
), this signal is invalid. (For the overview of
H
H
APPENDICES
A
)).
H
1
2
3
4
, 0146
), this
H
H
, 0146
), this
H
H
271