(10)Module-based parameter data (address: 0126
Address
Name
CH1
CH2
Counter function
0126
0146
H
H
selection
Function input logic
0127
0147
H
H
setting
Latch counter input
0128
0148
H
H
logic setting
294
• Set the counter function which becomes valid when the value in CH
Operation mode setting (address: 0120
• The following shows the setting range.
0: Count Disable Function
1: Latch Counter Function
2: Sampling Counter Function
3: Periodic Pulse Counter Function
4: Count disable/Preset/replace Function
5: Latch counter/Preset/replace Function
• The reflection timing of the setting value
When Initial data setting request flag (RY9) is turned off then on
• Set the logic setting of CH Function input terminal (FUNC1, FUNC2).
• CH1 FNC LED and CH2 FNC LED turn on with any setting value when a
voltage is applied.
• The following shows the setting range.
0: Positive Logic
1: Negative Logic
• The reflection timing of the setting value
When Initial data setting request flag (RY9) is turned off then on
• Set the logic setting of CH Latch counter input terminal (LATCH1,
LATCH2).
• CH1 LAT LED and CH2 LAT LED turn on with any setting value when a
voltage is applied.
• The following shows the setting range.
0: Positive Logic
1: Negative Logic
• The reflection timing of the setting value
When Initial data setting request flag (RY9) is turned off then on
to 0128
, 0146
H
H
Description
, 0140
) is Normal Mode (0).
H
H
to 0148
)
H
H
Default
0
0
0