The following processing is performed when CH PWM output start command (RY26, RY3E) is turned on to turn on CH PWM
output (RX26, RX3E).
• The values in CH PWM output assignment setting (RWw1D, RWw35), CH ON width setting (PWM output) (RWw1E to
1)
RWw1F, RWw36 to RWw37), and CH Cycle setting (PWM output) (RWw20 to RWw21, RWw38 to RWw39) are acquired.
• The PWM waveform is output from one of the coincidence output 1 to 4 terminals (EQU1 to EQU4) based on the settings. (The
PWM waveform is output starting with OFF.)
The PWM waveform continues to be output based on the acquired settings until CH PWM output start command (RY26, RY3E)
2)
is turned off or CH ON width setting change request (PWM output) (RY35, RY4D) is turned on.
When the values in CH PWM output assignment setting (RWw1D, RWw35), CH ON width setting (PWM output) (RWw1E to
RWw1F, RWw36 to RWw37), and CH Cycle setting (PWM output) (RWw20 to RWw21, RWw38 to RWw39) are changed, the
3)
PWM waveform is not changed. Only the value in CH ON width setting (PWM output) (RWw1E to RWw1F, RWw36 to RWw37)
can be changed by CH ON width setting change request (PWM output) (RY35, RY4D).
The following processing is performed when CH ON width setting change request (PWM output) (RY35, RY4D) is turned off
then on to turn on CH ON width setting change completed (PWM output) (RX35, RX4D).
• The value in CH ON width setting (PWM output) (RWw1E to RWw1F, RWw36 to RWw37) is acquired.
• The PWM waveform is output from one of the coincidence output 1 to 4 terminals (EQU1 to EQU4) based on the settings. The
4)
change is reflected immediately.
Turn off CH ON width setting change request (PWM output) (RY35, RY4D) when CH ON width setting change completed
(PWM output) (RX35, RX4D) turns on. CH ON width setting change completed (PWM output) (RX35, RX4D) turns off when
CH ON width setting change request (PWM output) (RY35, RY4D) is turned off.
The following processing is performed when CH PWM output start command (RY26, RY3E) is turned off to turn off CH PWM
5)
output (RX26, RX3E).
• Turn off the coincidence output 1 to 4 terminals (EQU1 to EQU4) immediately.