Mitsubishi Electric NZ2GFCF-D62PD2 User Manual page 309

Cc-link ie field network high-speed counter module
Table of Contents

Advertisement

(SM  1) + (LS  n1) + Processing time of the high-speed counter module (T
• SM: Scan time of the program in the master station
• LS: Link scan time
• n1: The value provided by rounding up the value after the decimal point of (SM  LS)
(c) Processing time (Normal value): Master station (RX)  Remote device station (RX)
The following shows the processing time required until Coincidence output 1 (RX10) is transmitted to the
master station after the high-speed counter module receives Reset command (Coincidence output 1) (RY10).
(The processing time required for transmitting Reset command (Coincidence output 1) (RY10) to the high-
speed counter module is not included.)
(SM  1) + (LS  n1) + Processing time of the high-speed counter module (T
• SM: Scan time of the program in the master station
• LS: Link scan time
• n1: The value provided by rounding up the value after the decimal point of (SM  LS)
(d) Processing time (Normal value): Master station (RWw)  Remote device station
(RWw)
The following shows the transmission time required for setting Point setting (Coincidence output 1) (RWw0 to
RWw1) to the high-speed counter module. (The processing time required for transmitting Setting change
request (Coincidence output 1) (RY14) to the high-speed counter module is not included.)
(SM  n2) + (LS  1) + Processing time of the high-speed counter module (T
• SM: Scan time of the program in the master station
• LS: Link scan time
• n2: The value provided by rounding up the value after the decimal point of (LS  SM)
APPENDICES
)
1
)
1
)
1
307
A