Error code
Classification
(hexadecimal)
0F40
Moderate error
H
1330
Moderate error
H
1341
Moderate error
H
1F00
Major error
H
1F20
Moderate error
H
1F30
Moderate error
H
*15
Minor error
050
H
Description and
Error name
cause
The lower 3 bits of
Input response time
Input response
setting (address:
time setting error
0001
) is set to 000b,
H
001b, or 010b.
The number of ON
Number of ON
times integration
times integration
function is enabled
function setting
when the cam switch
error
function is selected.
An extension output
module does not exist
where Cam switch
Cam switch output
output unit assignment
unit assignment
setting (address:
error
0104
) assigns the
H
module.
The extension module
is improperly
connected or an
Extension module
extension module not
1 connection error
allowed to be
connected has been
connected.
The external power
supply for the
extension output
External power
module is off while the
supply OFF error
external power supply
monitoring function is
enabled.
The parameter for
specifying the
Extension module
extension module type
parameter failure
has specified a type
different from the
connected one.
The value in CH
Sampling count value
(RWr12 to RWr13,
RWr2A to RWr2B),
CH Periodic pulse
count, difference value
CH
(RWr12 to RWr13,
Overflow/underflow
RWr2A to RWr2B), or
error (Sampling
CH Periodic pulse
count
count value update
value/Periodic
check (RWr16 to
pulse count,
RWr17, RWr2E to
difference value)
RWr2F) is outside the
range of -2147483648
to 2147483647.
 indicates the
channel where
settings are incorrect.
CHAPTER 11 TROUBLESHOOTING
Operation of when an error
occurs
The other
Error CH
CHs
*13
*13
*13
*13
*14
*13
*2
*3
Action
Set the lower 3 bits of Input
response time setting (address:
0001
) to a value other than
H
000b, 001b, and 010b, then turn
on Initial data setting request
flag (RY9).
Set Number of ON times
integration function enable
(address: 0202
) to 0000
, and
H
H
turn off then on Initial data
setting request flag (RY9).
Power off the module, and
connect an extension output
module where Cam switch
output unit assignment setting
(address: 0104
) assigns the
H
module. Then power on the
module.
Check the contact points on the
extension module, and if the
module is allowed to be
connected. If the same error
occurs again, a module failure
may be the cause. Please
consult your local Mitsubishi
representative.
• Check the external power
supply status for the external
output module.
• If this error occurs when the
system starts or stops,
change the timing of when
the external power supply
monitoring function is
enabled.
Correct the setting in Extension
module identification code
(address: 0200
) so that the
H
setting matches the connected
extension module and the
module points.
Adjust the values so that the
product of Input pulse speed
[pps]  Sampling/Periodic time
[s] is within the range.
229