Mitsubishi Electric NZ2GFCF-D62PD2 User Manual page 42

Cc-link ie field network high-speed counter module
Table of Contents

Advertisement

Signal direction: High-speed counter module 
Module
type
Device
number
CH1 Measured pulse value update flag reset
RX31
completed (Function input terminal)
CH1 Measured pulse value update flag
RX32
(Function input terminal)
CH1 Measured pulse value update flag reset
RX33
completed (Latch counter input terminal)
CH1 Measured pulse value update flag (Latch
RX34
counter input terminal)
CH1 ON width setting change completed (PWM
RX35
output)
RX36
CH1 Error status
RX37
CH1 Warning status
RX38
Use prohibited
RX39
CH2 Preset/replace completion
RX3A
Use prohibited
CH2 External preset/replace (Z Phase) request
RX3B
detection
RX3C
Use prohibited
RX3D
CH2 Counter function detection
RX3E
CH2 Cam switch execute/PWM output
CH2 Setting change completed (Sampling
RX3F
Main
counter/Periodic pulse counter)
module
CH2 Update flag reset completed (Latch count
RX40
value/Sampling count value/Periodic pulse
count value)
CH2 Update flag (Latch count value/Sampling
RX41
count value/Periodic pulse count value)
CH2 Latch count value update flag reset
RX42
completed (Latch counter input terminal)
CH2 Latch count value update flag (Latch
RX43
counter input terminal)
CH2 Update flag reset completed (Measured
RX44
frequency value/Measured rotation speed value)
CH2 Update flag (Measured frequency
RX45
value/Measured rotation speed value)
RX46
Use prohibited
RX47
Use prohibited
RX48
Use prohibited
CH2 Measured pulse value update flag reset
RX49
completed (Function input terminal)
CH2 Measured pulse value update flag
RX4A
(Function input terminal)
CH2 Measured pulse value update flag reset
RX4B
completed (Latch counter input terminal)
40
Remote input
Master/local module
Description
Remote output
Signal direction: Master/local module  High-
speed counter module
Device
number
CH1 Measured pulse value update flag reset
RY31
command (Function input terminal)
CH1 Pulse measurement start command (Latch
RY32
counter input terminal)
CH1 Measured pulse value update flag reset
RY33
command (Latch counter input terminal)
RY34
Use prohibited
CH1 ON width setting change request (PWM
RY35
output)
RY36
CH1 Error reset command
RY37
Use prohibited
RY38
CH2 Coincidence output enable command
RY39
CH2 Preset/replace command
RY3A
CH2 Count down command
CH2 External preset/replace (Z Phase) request
RY3B
detection reset command
RY3C
CH2 Count enable command
RY3D
CH2 Selected counter function start command
CH2 Cam switch execute command/PWM
RY3E
output start command
CH2 Setting change request (Sampling
RY3F
counter/Periodic pulse counter)
CH2 Update flag reset command (Latch count
RY40
value/Sampling count value/Periodic pulse
count value)
RY41
Use prohibited
CH2 Latch count value update flag reset
RY42
command (Latch counter input terminal)
RY43
Use prohibited
CH2 Update flag reset command (Measured
RY44
frequency value/Measured rotation speed value)
RY45
Use prohibited
RY46
Use prohibited
RY47
Use prohibited
CH2 Pulse measurement start command
RY48
(Function input terminal)
CH2 Measured pulse value update flag reset
RY49
command (Function input terminal)
CH2 Pulse measurement start command (Latch
RY4A
counter input terminal)
CH2 Measured pulse value update flag reset
RY4B
command (Latch counter input terminal)
Description