(2) Program condition
This program uses Coincidence output 1 and Coincidence output 2 of CH1 in the high-speed counter module.
The extension output module is used for outputting digital output signals and cam switch output signals.
(3) Initial setting description
(a) Remote buffer memory (parameter area) setting
Mode switch setting
Input response time setting
Output HOLD/CLEAR setting
Cyclic data update watch time setting
Comparison output setting
Coincidence output 1 channel assignment setting
Coincidence output 2 channel assignment setting
Coincidence output 3 channel assignment setting
Coincidence output 4 channel assignment setting
Coincidence output 1 comparison condition setting
Coincidence output 2 comparison condition setting
Coincidence output 3 comparison condition setting
Coincidence output 4 comparison condition setting
Preset/replace setting at coincidence output (Coincidence output 1)
Preset/replace setting at coincidence output (Coincidence output 2)
Cam switch output unit assignment setting
Cam switch output 1 channel assignment setting
Cam switch output 2 channel assignment setting
Cam switch output 3 channel assignment setting
Cam switch output 4 channel assignment setting
Cam switch output 5 channel assignment setting
Cam switch output 6 channel assignment setting
Cam switch output 7 channel assignment setting
Cam switch output 8 channel assignment setting
Cam switch output 9 channel assignment setting
Cam switch output 10 channel assignment setting
Cam switch output 11 channel assignment setting
Cam switch output 12 channel assignment setting
Cam switch output 13 channel assignment setting
Cam switch output 14 channel assignment setting
Cam switch output 15 channel assignment setting
Cam switch output 16 channel assignment setting
Coincidence output enable command setting
CH1 Operation mode setting
CH1 Count source selection
CH1 Pulse input mode
CH1 Counting speed setting
196
Setting item
Setting value
9: Automatical judgment mode (initial value)
5: 10ms (Initial value)
1: HOLD
10 (100ms)
Set a value according to the comparison output
function to be used.
0: CH1 (Initial value)
0: CH1 (Initial value)
1: CH2
1: CH2
0: Coincidence Output (Initial value)
1: Within-range Output
0: Coincidence Output (Initial value)
0: Coincidence Output (Initial value)
0: Present value not replaced (Initial value)
0: Present value not replaced (Initial value)
1: Stage 1
0: CH1 (Initial value)
0: CH1 (Initial value)
0: CH1 (Initial value)
0: CH1 (Initial value)
0: CH1 (Initial value)
0: CH1 (Initial value)
0: CH1 (Initial value)
0: CH1 (Initial value)
1: CH2
1: CH2
1: CH2
1: CH2
1: CH2
1: CH2
1: CH2
1: CH2
Set a value according to the command to be used.
Set a value according to the operation mode to be
used.
0: A Phase/B Phase (Initial value)
3: 2-Phase Multiple of 1
2: 200kpps