Mitsubishi MELSEC QD75P User Manual page 615

Positioning module
Table of Contents

Advertisement

15 TROUBLESHOOTING
Related buffer memory
address
Axis 1 Axis 2 Axis 3 Axis 4
Refer to Section 5.5
"List of condition data"
1540 1640 1740 1840 Axis 1 start data No.
1541 1641 1741 1841 Axis 2 start data No.
1542 1642 1742 1842 Axis 3 start data No.
1543 1643 1743 1843 Axis 4 start data No.
1500 1600 1700 1800
Refer to Section 5.3
"List of positioning data"
Set range
(Setting with sequence program)
<Condition operators>
Axis designation:
10
, 20
, 30
, 40
, 50
H
H
H
H
60
, 70
, 80
, 90
, A0
H
H
H
H
B0
, C0
, D0
, E0
H
H
H
H
Simultaneous
start axis start
data No.
0 to 600
<Positioning start No.>
1 to 600,
7000 to 7004,
9001 to 9004
<JUMP destination>
1 to 600
<Command speed>
1 to 1000000 [pulse/s]
1 to 2000000000 [mm/min or others]
15 - 11
Get other manuals https://www.bkmanuals.com
Normalize the condition operators.
,
H
(Refer to Section 5.5
,
H
Normalize the simultaneous start axis start data No.
(Refer to Section 10.5)
Normalize the positioning start No., positioning start
data (in block start), and positioning data (in JUMP
instruction).
Normalize the positioning data.
MELSEC-Q
Remedy
Da.16
)

Advertisement

Table of Contents
loading

Table of Contents