Mitsubishi MELSEC QD75P User Manual page 30

Positioning module
Table of Contents

Advertisement

1 PRODUCT OUTLINE
(2) Movement amount and speed in a system using worm gears
Pulse encoder
(PLG)
Servomotor
(b) Pulse train output from the QD75
1) As shown in Fig. 1.3, the pulse frequency increases as the motor
accelerates. The pulses are sparse when the motor starts and more
frequent when the motor speed comes close to the target speed.
2) The pulse frequency stabilizes when the motor speed equals the target
speed.
3) The QD75 decreases the pulse frequency (sparser pulses) to
decelerate the motor before it finally stops the output.
There will be a little difference in timing between the decrease in the
pulse frequency and the actual deceleration and stopping of the motor.
This difference, called "the stop settling time", is required for gaining a
stopping accuracy.
Speed V
Pulse droop
amount
Accel-
eration
Pulse train Rough
Fig. 1.3 QD75 output pulses
V
Workpiece
Worm gear
Table
R
L
P0
Fig. 1.4 System using worm gears
1 - 10
Get other manuals https://www.bkmanuals.com
Servomotor
speed
Pulse
distribution
Decel-
eration
Dense
Rough
A : Movement amount per pulse (mm/pulse)
Vs : Command pulse frequency (pulse/s)
n : Pulse encoder resolution (pulse/rev)
L : Worm gear lead (mm/rev)
R : Deceleration ratio
V : Movable section speed (mm/s)
N : Motor speed (r/min)
K : Position loop gain (1/s)
P
ε
: Deviation counter droop pulse amount
P0 : OP (pulse)
P : Address (pulse)
MELSEC-Q
Time t
Stop
settling time

Advertisement

Table of Contents
loading

Table of Contents