10 HIGH-LEVEL POSITIONING CONTROL
Example
Positioning
start
command
M104
Y10
Y10: Positioning start signal
X10: Start complete signal
M104: Positioning start command pulse
Creating the program
Set the block start data beforehand.
X10
TO
TO
10 - 26
Get other manuals https://www.bkmanuals.com
PLS
M104
<Pulse the positioning start command.>
H0
K1500
K7000
K1
H0
K1501
K1
K1
<Write the positioning start point No.>
SET
Y10
<Turn ON the positioning start signal.>
MELSEC-Q
<Write the positioning data No. 7000
for block positioning.>