10.5 - Operation in Output mode
RAD INT
A
command results in opening of the door, which
remains open for a user-modifiable duration time (see Changing
parameters) and then closes again.
10.6 - Operation in Input mode
RAD ESt
A
command results in opening of the door, which
remains open for a user-modifiable duration time (see Changing
parameters) and then closes again.
10.7 - Operation in Partial Opening mode
RAD INT
RAD ESt
A
or
the opening stroke is reduced to a percentage of the maximum
stroke that can be changed by the user (see Changing parameters).
The door remains open for a user-modifiable duration time (see
10.8 - Operation in Open mode
Positioning the selector in the Open position results in opening of
the door, which remains open until the position of the selector is
changed.
10.9 - Operation in block mode
Positioning the selector in the Lock position results in closing
of the door and subsequent activation of the electric lock. The
door remains closed and locked, ignoring any command (except
10.10 - Operation in Pharmacy mode
Positioning the selector in the Pharmacy position results in closing
of the door and subsequent activation of the electric lock. Only the
START, OPEN and CLOSE commands are accepted. The door

10.11 - OPEN and CLOSE commands

The OPEN command results in opening of the door, which remains
open until the CLOSE command is received. A
EST
command during closing results in immediate reopening.
The OPEN and CLOSE command are priority commands, they
cause opening or closing of the door, which remains open/closed

10.12 - START command

The START command results in opening of the door even in a
locked state. The door remains open in the manner defined by
parameter U (see Changing parameters) and then closes and
locks (only if the lock status persists). By changing the parameter
10.13 - STOP command (N.C.)
The STOP command results in immediate stopping of the door
and, as long as it remains active, any other command is ignored.
10.14 - PHOTO command (N.C.)
The PHOTO command causes the door to reopen if in the closing phase and, as long as it remains active, it does not allow it to be closed again.
64
command results in opening of the door;
RAD INT
RAD INT
RAD ESt
A
or
RAD INT
command during closing results in immediate reopening.
RAD INT
RAD ESt
A
or
RAD ESt
command during closing results in immediate reopening.
Changing parameters) and then closes again. A
ESt
command during opening is ignored.
RAD INT
RAD ESt
A
or
immediate reopening.
Note: in this mode the "CLOSE" command closes and reopens
the door. The "STOP" command stops the door.
START) until the position of the selector is changed.
opens only approximately 15 cm and the electric lock is activated
again when closed. This condition remains until the position of the
selector is changed.
for the entire duration of the command. The OPEN command has
RAD
or
priority over CLOSE. During the opening or closing performed with
the maintained OPEN or CLOSE commands, a
EST
or START command is ignored.
A PHOTO command during closing results in immediate reopening.
"U" to position 0 (zero) it becomes "step-by-step".
Note: this mode does NOT follow the "PARTIAL OPENING"
setting, therefore the "START" command always opens
completely.v
Except in the "OPEN" functionality.
command during opening is ignored. A
command during opening is ignored. A
RAD INT
command during closing results in
RAD INT
RAD
or
RAD
or