Download Print this page
Key Automation TURBO Instructions And Warnings For Installation And Use
Key Automation TURBO Instructions And Warnings For Installation And Use

Key Automation TURBO Instructions And Warnings For Installation And Use

Gear-motor for sliding gates
Hide thumbs Also See for TURBO:

Advertisement

Instructions and warnings for installation and use
TURBO
Gear-motor for sliding gates

Advertisement

loading
Need help?

Need help?

Do you have a question about the TURBO and is the answer not in the manual?

Questions and answers

Summary of Contents for Key Automation TURBO

  • Page 1 Instructions and warnings for installation and use TURBO Gear-motor for sliding gates...
  • Page 2: Table Of Contents

    INDEX Safety warnings pag. 10 Product overview pag. 12 Product description pag. 12 Model and technical characteristics pag. 12 Preliminary checks pag. 13 Product installation pag. 14 Installing pag. 14 Fixing pag. 14 Rack assembling pag. 14 Limit switch fixing pag.
  • Page 3 If in any doubt regarding installation, do not proceed if the power cable is damaged, it must be replaced by and contact the Key Automation Technical Service for the manufacturer or its after-sales service, or in all ca- clarifications.
  • Page 4 Key Automation reserves the right to amend fixed parts around it; these instructions if necessary; they and/...
  • Page 5: Product Overview

    2 - PRODUCT OVERVIEW 2.1 - Product description Irreversible electromechanical gearmotor for sliding gates operating at 24 Vdc and 230 Vac. (Fig.1) 2.2 - Model and technical characteristics CODE DESCRIPTION SC162 230 Vac gear motor with mechanical limit switches, gate maximum weight 1600 kg TECHNICAL DATA MODEL SC162...
  • Page 6: Product Installation

    4 - PRODUCT INSTALLATION 4.1 - Installation Respecting the overall size, fix to ground the base-plate through ATTENTION ! 4 sturdy screw-anchors (fig.3) or drown it into the concrete (fig.3). Plan for one or more sheathing for the passage of the power lines. The installer must verify that the working temperature range stated on the automation device is suitable for the location N.B.
  • Page 7 5 - TESTING AND COMMISSION THE AUTOMATION The system must be tested by a qualified technician, who must the relevant regulatory requirements, especially with the EN12453 perform the tests required by the relevant standards in relation to standard which specifies the test methods for gate and door the risks present and must check that the installation complies with automation systems.
  • Page 8 IMAGES Fig. 1 EN - Product description Fig. 2 EN - Typical Installation Safety edges are required to protect trap and crush points Fig. 3 EN - Installing Bend rags down into concrete for maximum grip...
  • Page 9 Fig. 4 EN - Fixing Fig. 5 EN - Rack assembling 90mm Fig. 6 EN - Limit switch fixing...
  • Page 10 Fig. 3 EN - Emergency unlocking...
  • Page 11 Il sottoscritto Nicola Michelin, Amministratore Delegato dell’azienda The undersigned Nicola Michelin, General Manager of the company Key Automation S.r.l., Via Meucci, 23 - 30027 San Donà di Piave (VE) – ITALIA dichiara che il prodotto tipo: declares that the product type:...
  • Page 12 Key Automation S.r.l. Via Meucci 23 - 30027 San Donà di Piave (VE) T. +39 0421 307456 - F. +39 0421 65698 Instruction version info@keyautomation.it - www.keyautomation.it 580ISSC-50 REV.08...