TUXEDO TOUCH WI-FI INSTALLATION & SETUP GUIDE

Supplementary Power Supply Connections

IMPORTANT NOTES:
• If an auxiliary power supply is used, you MUST connect a common ground as shown above.
• When Tuxedo is powered from an auxiliary power supply, always apply power to the control panel first and
then to Tuxedo. Failure to observe this sequence results in improper operation of the keypad and may result
in an ECP Error indication.
• Supplementary external power supply must be listed to UL603 for UL Burglary Installations and UL1481
for UL Residential Fire Installations.

Programming the Control Panel

Conventional Programming Methods

The keypad is not fully operational unless its address in the control panel has been enabled (set as an alpha
console) AUI type device, and assigned to a partition (where applicable). For a list of compatible alarm systems,
refer to the Control Panel Compatibility for the quantity of keypads that may be used with the Tuxedo and the
required control panel's software revision level.
We recommend that you use either a standard alpha keypad or the keypad in Console Emulation Mode when
programming the control panel. When in the Console Mode, the keypad emulates an alpha keypad and the
programming of the panel is performed following the procedures provided in your panel's Installation and Setup
Guide.
NOTE:
When programming your control panel, if you change the zone types for your emergency zones you may disable the
emergency icons in the keypad. The emergency icons in the keypad are active for zone types 06 (Silent Panic
Button), and 07 (Panic Button), 08 (Medical Button), and 09 (Fire Button). Additionally, the Medical button is also
compatible with a zone type 15 (24-Hour Medical) for panels that contain this zone type. Review the table under
the section Control Panel Compatibility for the total number of keypads compatible and the revisions required.

Residential Control Panels

Residential Control Panels consist of the VISTA-20P, VISTA-21IP and VISTA-15P and equivalents.
• Addresses one and two (in field *189) are enabled by default. If the defaults have been changed, enable these
addresses (in field *189) using an alpha-keypad and the Data Field Programming procedures located in the
panel Installation and Setup Guide.
• If using Resideo Total Connect™ Remote Services, here in referred to Total Connect):
o Resideo residential control panel revision 9.18 (3.13 for the Vista-21IP) and under must program the
Remote Interactive Service option in the second location in *91 to a 2 (by default location 1 is set to 8, so the
entry would be *91=82)
o Resideo residential control panel revision 10.0 (4.21 for the Vista-21IP) and higher supports the RIS option
by default, hence there is no programming location to enable.
Common Ground