Appendix A: Important Notes

For additional troubleshooting procedures, refer to the Control Panel Installation Guide.

General Notes

• You may check to see whether the Chime Mode is ON or OFF by viewing the keypad Operating Modes screen as
described in the "Operating Modes" section.
• Note that some displays on the keypad may not have enough space to display the full name of a partition. When
this occurs, the display shows as many characters as possible starting at the beginning of the partition name. We
recommend that the partition name be kept to a maximum of seven characters to ensure the "H" which indicates the
home partition may be seen.
• "Exit Error" and "Auto Arm Alert, Please Leave Now" messages are not displayed by the keypad.
• When the system has 6150Vs or 6160Vs, and 6271Vs attached, the Additional Console setting in the 6150Vs
(displayed as A on the 6150V) must be set to one and the Additional Console setting in the 6160Vs must be set to
Yes.

Commercial System Notes

• If the Aux Relay function is set for alarm silenced by User Code + # + 67, this command may only be entered in the
console emulation mode.
• Do not use the common lobby logic function.
• If fields 2*22 (Display Fire Alarms of other Partitions), 2*23 (Display Burg & Panic of other Partitions), or 2*24
(Display Troubles of other Partitions) are enabled, the zones that created the conditions cannot be viewed. You
must go to that zone's home partition to view.
• If field 1*11 (Zone Bypass After Disarm) is enabled, you must use the keypad's Console Emulation Mode and the
commands "Code" + "64" (unbypass all) or "Code" + "6" + "Zone Number" (unbypass zone) to remove zone bypasses.
• The First to Alarm Display Lock feature (field 1*10) is not supported by the keypad.
• RF Low Battery messages are not supported by the keypad except in the Show Zones screen where a Battery Icon is
displayed for the zone with the low battery.

Residential System Notes

• If the Clean Me option is set, when the maintenance signal is received a "Fire Maintenance" message and the
Display Faults is shown. However, if you display the faults, zone 1 is not shown as a faulted zone.
• If RF Jam Reports are selected and RF Jam is detected, the User Authorization screen displays "Trouble ZN100 RF
Receiver." If you enter the console emulation mode, the display shows "Check 90 RF Receiver Jam."
• Do not use the Custom Word reminder feature.

User Related Notes

• Users added to the system using the keypad graphic user screen must be deleted from the keypad using the graphic
screen as well. Deleting users from the panel by any other means (alpha keypad, console emulation mode, or
Compass downloader) does not automatically delete them from the keypad.
• If the panel has exit tones enabled and you arm the system in the Away mode, the keypad beeps continuously
throughout the exit period.
• Use the console emulation mode for the following functions:
• Programming more than 10 system users.
• Programming the Pager report option for users of residential control panels (e.g., VISTA-15P/20P).
• Special Function Key operations (such as macros or single-button paging).
• End-User Scheduling.
• To check for an "Alarm Cancelled" message (on commercial panels only) if this feature has been enabled in the
system.
TUXEDO TOUCH WI-FI INSTALLATION & SETUP GUIDE