Association Details

Each Z-Wave enabled device has a maximum number of secondary controllers, in which it has the ability to send
updates. Example, a thermostat may have the ability to send up to five additional Tuxedo's on the same network.
However, other manufacturers may not have that ability (as depicted in the table below).
NOTE: If the value is zero, the device will only report status to the primary Tuxedo and the user will need to refresh the
keypad to get the latest device status. If the value is one, then it will report status to the primary Tuxedo and one other
secondary controller (Tuxedo).
Z-Wave Device
Binary Switches
Multilevel Switches

Z-Wave Network Update

After all Z-Wave devices have been successfully enrolled, you can perform a Z-wave network update to individual devices
or the whole network.

Individual Device Update

1. Press the device, and then press Search Devices
2. One of three separate messages are display: "Update failed," "Update success," or "Update Timed Out."
• If the update fails, move device within closer range of each other or try to add a repeater device in between to
extend the range.
If the update is successful then it has remapped the route to the device.

Complete Network Update

This option is helpful when Z-Wave network issues arise. When Scan
the best path (route) to each device (which remaps the Z-Wave network).
1.
Press Scan
.
2.
Tuxedo will scan the Z-Wave network and complete the discovery. The onscreen message "Discovery is about
to start please wait..." displays.
3.
When done, the message displays "Discover Result...
device list for those devices. Try to add repeater devices to extend the range or move devices closer to each
other. Please run the discovery process again."
NOTES:
This process may take several seconds/minutes based on the number of devices enrolled.
If user wants to continue with other operations, they can close the pop up and go navigate to the home screen.
The Z-Wave install screen will be blocked and enter Z-Wave screen again until the status refresh complete.
The message Discovery in progress, remaining time XX:XX. Device Found: X/XX.
o Remaining time is determined by the number of devices found.
o Device found, will list the total number of devices found and scroll through the devices as they are found.
Manufacturer
Thermostat
Trane®
CT100 & CT32®
Resideo ZWSTAT®
Intouch®
Current innovation®
Wayne Dalton®
Locks
Schlage®
Kwikset®
Yale®
Garage Door
Linear®
Water valve
Fortrezz®
Leak Gopher®
GE®
Homemanagables®
Home Settings®
Wayne Dalton®
GE®
Associations Supported
5
2
5
0
2
0
2
5
5
1
0
5
0
0
0
0
0
.
is pressed the Z-Wave controller searches for
1 device(s) are not found during discovery. See the
Follow the suggestions in the message.