Defining Event Types - Honeywell Home Tuxedo Touch TUXWIFIS Installation And Setup Manual

Hide thumbs Also See for Tuxedo Touch TUXWIFIS:
Table of Contents

Advertisement

Defining Event Types

To receive email notification when specific events occur, the "event type" must be defined. Scenes can be set to trigger
based on the status of these settings. From "System Events Notification" screen, set the following event types:
Event
Security
Zones
Occupancy (automation
mode only)
Thermostat
Door Lock
Garage Door
Water Valve
Recording
NOTE: An SD Card Full Message displays when 90% of the usable space on the SD card is used.
Troubleshooting
If an error is returned through the listed SMTP email provider stating that the email has blocked a sign in
attempt, return to the SMTP server page and verify the email settings. The Tuxedo will populate an error that
states "Warning: Email sending failed. Please check SMTP settings." If this is the case, check the security
settings for the email chosen through the provider.
The customers email server may see a frequently sent message and could perceive it as a threat. The result is
the email provider will lock down the email receive and send. You will have to contact their email provider to
resolve.
Definition
(Normal mode; current home partition only.) Press the desired check box next to Disarm, Arm Away
Secured, Arm Stay and/or Alarm.
(Normal mode; current home partition only.) Press the desired check box next to Alarm, Trouble,
and/or Restore.
Press the desired check box next to Home, Away and/or Night. NOTE: If in Commercial mode, the
occupancy options are Open, Close, and Night.
Select a thermostat from the drop-down list. Press the desired check box next to TEMP ABOVE /
TEMP BELOW. Enter the temperature degree that triggers an Email when the temperature rises
above or falls below the set point.
Select the desired door lock from the drop-down list. Press the desired check box next to UNLOCKED
and/or LOCKED.
Select the desired garage door from the drop-down list. Press the desired check box next to CLOSED,
OPENED and OPERATION DISABLED/FAILED.
Select the desired water valve from the drop-down list. Press the desired check box next to OPENED
and/or CLOSED.
WARNING: The Leak Gopher® water valve does not send status to the keypad when operated
manually. It is not recommended to select this device as an Email trigger.
Select an Email address and highlight Recording. Enable the desired check box next to "On Event
Recording" and/or "SD Card Memory Full."
NOTE: An SD Card Full Message displays when 90% of the usable space on the SD card is used.
TUXEDO TOUCH WI-FI INSTALLATION & SETUP GUIDE
20

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tuxedo touch tuxwifiw

Table of Contents