3.2

503 Series Zoned Power example

In the example shown below there are two Zoned Power Manifold blocks used. One is a "W" wiring option
and the other is a "V" wiring option. The first (5) stations of the manifold assembly get their power from
the M12 4 Pin connector at station one. The next (5) stations get their power from the M12 4 Pin
connector at station six. Each of these "Zones" can be individually switched of if the machine or process
requires. This example is considered a manifold with (2) Power Zones. The Main Power (7/8" MINI) cannot
be considered or used as a Power Zone; Switched Power (Solenoid/Output Power) MUST be present for
control to the solenoids
24 VDC
V
a
l
v
e
&
O
u
t
p
u
t
NOTE!
G3 Series PROFIBUS-DP
N
o
d
e
&
I
n
p
u
t
The 0 VDC reference for the +24 VDC applied to Pin 4 of the M12 connector
as the one used on G3/580/Terminal Strip/25 or 37 Pin Sub-D/19 or 26 Pin Round Connector.
If multiple 24 VDC power supplies are used the 0 VDC references of each supply
common.
TDG3PTTM1-11EN
Subject to change without notice
TM
V Wiring Option
07/2020
www.asco.com
Technical Manual
W Wiring Option
MUST
be the same
MUST
be
3-17