Distribution - Emerson Aventics G3 Series Technical Manual

Profibus dp-v0 dp-v1
Hide thumbs Also See for Aventics G3 Series:
Table of Contents

Advertisement

7. Distribution

Distribution of I/O capability can be easily achieved with the G3 platform by means of Sub-Bus modules. I/O modules,
valve manifolds and/or a combination of both can be simply separated from the main manifold and distributed via a
sub-bus communication cable. The G3 platform uses the same I/O modules on the main manifold as on the
distribution chain. The main communication module can control up to 16 I/O modules either on the main manifold or
as part of the sub-bus connections. To utilize the sub-bus distribution capabilities the Sub-Bus OUT module must be
located on the end of the main communication manifold and a Terminator Module must be located at the last sub-bus
component.
Example 1
5
2
5
10
6
5
Detail No.
1
2
Sub-Bus Power Cable (Can be connected to separate power supply for isolated power control)
3
4
5
6
7
8
9
Aux. Power IN (Used to augment Input power and/or supply power to Output modules)
10
G3 Series PROFIBUS-DP
7
Power
Supply
7
4
7
9
Main Communication Module (Node)
Distributed Sub-Bus Valve Module
Sub-Bus IN module
Sub-Bus OUT module
Sub-Bus Communication Cable
Terminator Module (Used to terminate sub-bus)
Aux. Power OUT (Can be used to supply power to distributed modules)
TDG3PTTM1-11EN
Subject to change without notice
www.asco.com
Technical Manual
TM
Fieldbus network
1
3
8
7
Description
I/O Modules
07/2020
Main Fieldbus
Valve Manifold
with I/O
Distributed
Sub-Bus
Valve
Manifold
4
Distributed
Sub-Bus I/O
Modules
9
7-43