13.

PROFIBUS-DP

13.1

Parameters

The Aventics' G3 PROFIBUS-DP
behaves in certain instances. The following are descriptions of these device parameters.
Parameter Name
Address
Brightness
Profibus Mode
I/O Allocation
Coils
Output Idle Action
Output Fault
Action
SSA Lock
G3 Series PROFIBUS-DP
Configuration and Commissioning
TM
node allows the user to set many user options which define how the manifold
TM
Description
Node address
Adjust brightness of graphic
display
Selects GSD file/Diagnostic
capability DPV0 or DPV1
Allocates how many valve output
points are mapped (8, 16, 24, 32)
Determines whether to use idle
value attribute or hold last state
Determines whether to use idle
value attribute or hold last state
Determines how the network
address may be set
TDG3PTTM1-11EN
Subject to change without notice
www.asco.com
TM
Technical Manual
Settable Via
Softwar
Display
MCM
e
X
X
X
X
X
X
07/2020
X
X
X
X
X
X
13-114