G3 Series PROFIBUS-DP
Sub-Bus In Modules
Used to distribute I/O assemblies that do not have valves
Must be installed to the right of the I/O modules.
o
Sub-Bus In - 5 pin M12 male communication connector.
Must be connected to the Sub-Bus Out connector of the previous assembly
o
Carries 24 VDC power for electronics of module
o
Aux. Power In - 4 pin M12 male connector.
Aux power is required for Output modules. This connection also allows Output power to be interrupted
o
to all Output modules connected to this module.
Aux. Power is optional for Inputs. Power from the Sub-Bus In connection is used to power
o
sensors but can be augmented, if necessary, by adding additional power to this connector.
Description
Sub-Bus In module with Din Rail Mounting
Sub-Bus In module without Din Rail Mounting
TDG3PTTM1-11EN
07/2020
Subject to change without notice
www.asco.com
Technical Manual
TM
Part Number
240-246
240-185