14.7
Example No. 4
Assumed Settings
a.
Double Z-Boards
TM
b.
I/O Modules and mapping schemes are
identified by their corresponding color.
Manifold I/O Configuration
Pos
Module Type
No.
1
16I PNP
240-205
2
4I Analog
240-212
3
16I PNP
240-205
4
16I PNP
240-205
Local Valves:
How to Order
Qty
Part Number
1
8503AV3F300VA00
6
R501A1B40MA00F1
3
K502AMM22MA0010
1
G3PT102D0E44
1
240-205
1
240-212
ASSEMBLED
1
G3DS302R0STD
1
240-205
1
240-205
ASSEMBLED
NOTE!
When the 12 End
Solenoid is
Energized, the 2 port
is pressurized
G3 Series PROFIBUS-DP
used with all valves
In
Out
Part No.
Bytes
2
0
8
0
2
0
2
0
0
4
Total:
14