Setting The Liquid Concentrate Empty Signal Sensor - ProMinent DULCODOS ULIa Assembly And Operating Instructions Manual

Polymer preparation system
Table of Contents

Advertisement

Metering pump and additional components
11.3

Setting the liquid concentrate empty signal sensor

Installation and use:
82
The scope of delivery includes:
Capacitive switch: CQF16.
n
Bracket: BEF
2
.
n
2 foam pads, 3 mm thick, to mount the pipe.
n
2 adhesive pads, 1 mm thick, for screwless installation on the
n
surface.
Quick start.
n
Ä Chapter 6.3.3 'Option: Empty signal for concentrate
See also
tank' on page 44
1.
The sensor can be installed horizontally or vertically.
Fig. 52: Tank (1) and sensor (2)
2.
Fix the sensor (2) to the outside of the supply drum (1) using
the fastening strap supplied.
3.
Adjust the sensor flexibly to the required empty signal
warning level.
Calibration: No calibration required with supply drum wall thick‐
nesses of 0.5 ... 6 mm.
1
2
A3619