The previous knowledge how the "Dryer Profile" works and where it's based on:
A starting point for the Dryer Profile has to be selected by clicking (highlighting) onto the last
important line of archived board maps for the given board map binary archive file.
The algorithm to generate the Dryer Profile works reverse from the last chosen (highlighted)
board map entry and tries an averaging per deck regarding the preset average count. If the
preset average count isn't reached for any deck average calculation, an error message will be
displayed to inform the user to review the board table and the average count.
After the selection of "Dryer Profile" and the confirmation to "Show Dryer Profile", an empty (black)
historical dryer profile will be displayed. First thing to do is to set the weighting factor for averaging in
the right lower window corner. Afterwards click onto the "Start: Calculate Dryer Profile" button in the right
lower display corner for the dryer profile calculation. The reverse averaging per deck starts, beginning
from the last highlighted one up to the point, where the average weighting count for every deck is
reached. Adapt the weighting factor for averaging in case of deck weighting problems. If you modify the
weighting factor for averaging, please restart the calculation of the dryer profile and wait until it's finished
and the display is renewed. Above the "Start: Calculate Dryer Profile" button is an "Inverted Deck Order"
checkbox, which can be activated to alter the deck display order.

5.3.1.1.6 The Settings selector in the menu bar

Figure 99: TIP900 – Log Viewer display to set temperature unit & language
The "Settings" selector is to set the display "Temperature Unit" and "Language". For the temperature
unit selection you can choose between the units, displayed in °C or °F. All installed display language
variants will be listed, where you are able to select from.

5.3.1.1.7 The About selector in the menu bar

Figure 100: TIP900 – Log Viewer display About the integrated help function and SW information
The TIP900 – LogViewer SW help function allows to search for several specific topics.
The TIP900 – LogViewer information screen displays the creator, the copyright, the version and
trademark information of the SW.
TIP900
Rev. E1 Feb 2016
Operation
89