Tip900Sys (Ir Temperature Sensor Connection Box To Network) - Fluke TIP900 Operating Instructions Manual

Wallboard temperature imaging & profiling system
Table of Contents

Advertisement

Technical Data

3.1.4 TIP900SYS (IR Temperature Sensor Connection Box to network)

Type
Accuracy
mA/V output
TC output
Temperature Resolution
mA/V Output
Temperature Coefficient
mA/V Output
TC Output
Emissivity
Transmission
Loop Time
mA/V Output
digital
Voltage Supply
Power Consumption
Alarm Output
USB Interface
Analog Outputs
Output 1
TC
Output 2
External Inputs
FTC1-3
FTC1
FTC2
FTC3
Ambient Temperature
Storage Temperature
Rating
Relative Humidity
EMC
Vibration
Shock
Weight
Material
20
RAYMI3COMME
± 1°C
± 1.5°C
± 0.1°C (± 0.2°F) / 12 bit
± 0.02 K / K
± 0.05 K / K
0.100 to 1.100
0.100 to 1.000
8 ms
18 ms * number of connected heads
8 to 32 VDC (24 VDC from Rittal cabinet)
max. 6 W
1 potential-free relay output, 48 V / 300 mA
Relay with wear-free contacts (solid state relay)
for target temperature or head ambient temperature,
electrically isolated from power supply
Version: 2.0, Connector on the board: type Mini-B
0 to 5/10 V output for head ambient temperature and object
temperature, electrically not isolated from power supply
Thermocouple (type J, K, R, or S)
0 to 20 mA (active), 4 to 20 mA (active), 0 to 5 V, 0 to 10 V
electrically not isolated from power supply
3 inputs are available useable in different modes:
Emissivity control: 3 bit digital coded, 0 to VSS
Emissivity control: analog, 0 to 5 VDC
Ambient temperature compensation analog: 0 to 5 VDC
for trigger/hold/laser functions, 0 to VSS
-10 to 65°C (14 to 149°F)
-20 to 85°C (-4 to 185°F)
IP65 (NEMA-4) / IEC 60529
10% to 95% non-condensing
EN 61326-1:2006
11 to 200 Hz, 3 g above 25 Hz operating, 3 axes / IEC 60068-
2-6
50 g, 11 ms, operating, 3 axes / IEC 60068-2-27
370 g (13 oz)
die-cast zinc enclosure
Rev. E1 Feb 2016