Maintenance Information for the Temperature Compensation Sensor

Figure 47: Maintenance tab of Temperature Compensation in Supervisor mode

If the Temperature Compensation box, which adapts the temperature compensation sensor head via
Ethernet to the TIP900 network, is not accessible, the MI3-Box Ethernet status changes from green to
red background color. In status red, no valid temperature values will be measured.
1
Object Temperature:
Current Trigger Temp.:
2
Head Ambient Temp.:
3
Delta Threshold Temp.:
4
TIP900
3
4
Shows the current gypsum wallboard surface temperature of a passing
wallboard at a specific measurement position, close to the kiln exit. The
specific measurement position depends on the number of dryer decks
and the area, where the best stable kiln exit ambient temperature is.
The object temperature is acquired by the IR sensor head, connected
to the MI3-Box.
This is the value, which has to be achieved to indicate a trigger. The
value is based on the measured ambient temperature plus a defined
trigger threshold.
The Head Ambient Temperature is measured by a standard
temperature sensor, which is integrated in the sensor head to
determine the stable ambient temperature at the measurement
position.
It is the threshold plus the measured Head Ambient Temperature,
which has to be exceeded to indicate, that a dried gypsum wallboard
passes the sensor. The Delta Threshold Temperature value will be set
globally under the configuration item and just displayed 1:1 herein.